Another station via a co-existence network
Access by specifying the network number and the station number via another station on CC-
Link
The following table shows the accessible route to a target station from a station, on which an MES interface module is
mounted by specifying the network number and the station number of the target station. In this route, another station on CC-
Link is accessed first (first route), then a target station is accessed from there.
: Accessible, : No combination
First access
Second access route (co-
route
existence network)
CC-Link
CC-Link IE Controller Network
CC-Link IE Field Network
MELSECNET/H network
Ethernet
*1 It can access to an RnENCPU only in a single CPU system.
*2 No combination with the MELSECNET/H network for process CPUs and safety CPUs
*3 Can be accessed only when using an RD81MES96N.
*4 It is also supported by a QCPU (Q mode) for which the MELSOFT connection extended setting was set.
Access from another station specified by the network number and the station number on CC-
Link
The following table shows the accessible route to a target station from a station, on which an MES interface module is
mounted, by specifying the start I/O No. of a module that is routed through and the station number of the target station. In this
route, another station on CC-Link is accessed first by specifying the network number and the station number (first route), then
the target device is accessed from there.
: Accessible, : No combination
First access route
CC-Link IE Controller Network
CC-Link IE Field Network
MELSECNET/H network
*4
Ethernet
*1 It can access to an RnENCPU only in a single CPU system.
*2 No combination with the MELSECNET/H network for process CPUs and safety CPUs
*3 Can be accessed only when using an RD81MES96N.
*4 It is also supported by a QCPU (Q mode) for which the MELSOFT connection extended setting was set.
2 SPECIFICATIONS
30
2.2 Access Specifications for a CPU Module
Access target device type (series)
RCPU
Program
mable
controll
er CPU/
Process
CPU/
Safety
CPU
(CPU No.1
to 4)
*4
Second access
Access target device type (series)
route (co-
RCPU
existence
Program
network)
mable
controlle
r CPU/
Process
CPU/
Safety
CPU
CC-Link
(CPU No.1
to 4)
QCPU (Q mode)
C
Program
Controll
mable
er
controll
module
er CPU/
Process
CPU
*1*2
(CPU No.1
(CPU No.1
to 4)
to 4)
QCPU (Q mode)
C
Program
Controll
mable
er
controlle
module
r CPU/
Process
CPU
*1*2
(CPU No.1
(CPU No.1
to 4)
to 4)
LCPU
FX5CPU
C
Program
Controll
mable
er
controll
module
er CPU
(CPU No.1
*3
to 4)
LCPU
FX5CPU
C
Program
Controll
mable
er
controlle
module
r CPU
*3
(CPU No.1
to 4)
FXCPU