Constant

The following tables show the data type specifications for a constant according to the classification.
Data type
The data type of the constant is checked by MES Interface Function Configuration Tool not an MES interface module.
Integer
Data type
Usable character
Integer
-, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
Real number
Data type
Usable character
Real number
-, E, .(decimal point), 0, 1, 2, 3, 4, 5,
6, 7, 8, 9
*1 '-123.456789012345e-222' and '0.00000123456789012345' etc. can be set. '1.23456789012345000000' etc. cannot be set.
Character string
Data type
Character string
[Unicode]
2 SPECIFICATIONS
50
2.4 Data Specifications
Minimum value
-2147483648
(Minimum value of a signed 32-bit
integer)
Minimum of the
absolute values
2.22507385850721E-308
Usable character
Printable characters including the blank (U + 0020)
(Escape sequences are handled without converting into control characters. (\n, etc.))
Maximum value
4294967295
(Maximum value of an unsigned 32-bit
integer)
Maximum of the
Maximum number of
absolute values
significant digits in
the mantissa part
1.79769313486231E308
15 digits
Maximum length of character
string
255 characters