Preparation For Installation - Samson 3351 Mounting And Operating Instructions

Pneumatic on/off valve
Table of Contents

Advertisement

Installation
easily access the device from the work posi-
tion.
Pipeline routing
The inlet and outlet lengths (see Table 5-1)
vary depending on several variables and
process conditions and are intended as rec-
ommendations. Contact SAMSON if the
lengths are significantly shorter than the rec-
ommended lengths.
To ensure that the valve functions properly,
proceed as follows:
Î Observe the recommended inlet and
outlet lengths (see Table 5-1). Contact
SAMSON if the valve conditions or states
of the medium process deviate.
Î Install the valve free of stress and with the
least amount of vibrations as possible.
Read information under "Mounting posi-
tion" and "Support or suspension" in this
section.
Î Install the valve allowing sufficient space
to remove the actuator and valve or to
perform service and repair work on
them.
Mounting position
Generally, we recommend installing the
valve with the actuator upright and on top of
the valve.
Î Contact SAMSON if the mounting posi-
tion is not as specified above.
5-2
Support or suspension
Note
The plant engineering company is responsi-
ble for selecting and implementing a suitable
support or suspension of the installed control
valve and the pipeline.
Depending on the valve version and mount-
ing position, the valve, actuator and pipeline
must be supported or suspended.
Valves, which are not installed in the pipe-
line in the upright position with the actuator
on top, must be supported or suspended.
Valve accessories
Î During connection of valve accessories,
make sure that they are easily accessible
and can be operated safely from the
work position.
Vent plugs
Vent plugs are screwed into the exhaust air
ports of pneumatic and electropneumatic de-
vices. They ensure that any exhaust air that
forms can be vented to the atmosphere (to
avoid excess pressure in the device). Further-
more, the vent plugs allow air intake to pre-
vent a vacuum from forming in the device.
Î Locate the vent plug on the opposite side
to the work position of operating person-
nel.

5.2 Preparation for installation

Before installation, make sure the following
conditions are met:
− The valve is clean.