@® WARNING lamp
Blinks or lights up when one or more warning indicators on the display window
@ blink or light up.
Blinks when
—the recording cannot be made because of some problem in the recording
circuit.
—the drum servo is not locked.
—the heads are contaminated.
—the tape is slack.
—the tape is nearly at its end.
—the battery is nearly exhausted.
Lights up when
—moisture has condensed on the head drum.
—the tape is at its end.
—the battery is exhausted.
CH-1 PEAK/CH-2 PEAK (audio channel 1, 2 peak level) lamps
Light up when audio channels 1 or 2 input increase by +6 dB.
Level meters
Indicate the level of audio channels 1 and 2 when the MONITOR
SELECT
LNG/AFM
switch
@ is set to LNG, and the level of audio channels 3 and 4 when
the switch is set to AFM. The righthand meter (CH-2/CH-4/BATT) indicates the
battery condition when the BATT CHECK button @® is pressed.
Audio level of the channel selected by the
MONITOR SELECT LNG/AFM: switch
CH-1/CH-3
GH-2/CH-4/BATT
Battery condition
®
BATT CHECK (battery check) button