Mitsubishi Electric MELSEC QS Series User Manual page 116

Cc-link safety system master module
Hide thumbs Also See for MELSEC QS Series:
Table of Contents

Advertisement

8
PROGRAMMING SPECIFICATIONS
The following tables show the station numbers and corresponding buffer memory
addresses. The Slave station offset, size information area is not auto-refreshed. For
checking the data, use the monitoring function of GX Developer.
Table of station numbers and corresponding buffer memory addresses
Buffer
Station
Station
memory
number
number
address
1
2E0
to 2E3
H
H
2
2E4
to 2E7
H
H
3
2E8
to 2EB
H
H
4
2EC
to 2EF
H
H
5
2F0
to 2F3
H
H
6
2F4
to 2F7
H
H
7
2F8
to 2FB
H
H
8
2FC
to 2FF
H
H
9
300
to 303
H
H
10
304
to 307
H
H
11
308
to 30B
H
H
12
30C
to 30F
H
H
13
310
to 313
H
H
(4) Slave station offset, size information
8
- 13
8.2 Buffer Memory
8.2.2 Buffer memory details
Buffer
Station
memory
number
address
14
314
to 317
27
H
H
15
318
to 31B
28
H
H
16
31C
to 31F
29
H
H
17
320
to 323
30
H
H
18
324
to 327
31
H
H
19
328
to 32B
32
H
H
20
32C
to 32F
33
H
H
21
330
to 333
34
H
H
22
334
to 337
35
H
H
23
338
to 33B
36
H
H
24
33C
to 33F
37
H
H
25
340
to 343
38
H
H
26
344
to 347
39
H
H
This area stores allocation data for RX/RY/RWw/RWr to each station number.
"Table8.4 Buffer Memory Address Mapping for Station Numbers and RX/RY/RWw/
RWr Offset and Size" shows the relation between buffer memory addresses and
information to be stored.
(a) Offset
The head buffer memory address of RX/RY/RWw/RWr that is allocated to each
station is stored.
If two or more stations are occupied, a value is stored only in the head buffer
address area of the station No.
(For example, if station No.1 occupies two stations, a value is stored only in the
RX/RY/RWw/RWr offset area of station No.1, and the RX/RY/RWw/RWr offset
area of station No.2 stores the head buffer memory address size of the
corresponding area.)
(b) Size
The size of RX/RY/RWw/RWr that is allocated to each station is stored in word
units.
Any size less than 1 word is rounded to 1, and 1 is stored.
For a reserved station, 0000
(For example, if station No.1 occupies two stations, a value is stored only to the
RX/RY/RWw/RWr size of station No.1, and the RX/RY/RWw/RWr size of station
No.2 stays at default value (0000
Buffer
Station
memory
number
address
348
to 34B
40
37C
H
H
34C
to 34F
41
380
H
H
350
to 353
42
384
H
H
354
to 357
43
388
H
H
358
to 35B
44
38C
H
H
35C
to 35F
45
390
H
H
360
to 363
46
394
H
H
364
to 367
47
398
H
H
368
to 36B
48
39C
H
H
36C
to 36F
49
3A0
H
H
370
to 373
50
3A4
H
H
374
to 377
51
3A8
H
H
378
to 37B
52
3AC
H
H
is stored.
H
).
H
Buffer
Station
memory
memory
number
address
address
to 37F
53
3B0
H
H
to 383
54
3B4
H
H
to 387
55
3B8
H
H
to 38B
56
3BC
H
H
to 38F
57
3C0
H
H
to 393
58
3C4
H
H
to 397
59
3C8
H
H
to 39B
60
3CC
H
H
to 39F
61
3D0
H
H
to 3A3
62
3D4
H
H
to 3A7
63
3D8
H
H
to 3AB
64
3DC
H
H
to 3AF
---
H
H
Buffer
to 3B3
H
H
to 3B7
H
H
to 3BB
H
H
to 3BF
H
H
to 3C3
H
H
to 3C7
H
H
to 3CB
H
H
to 3CF
H
H
to 3D3
H
H
to 3D7
H
H
to 3DB
H
H
to 3DF
H
H
---

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-qs0j61bt12

Table of Contents