Network number and station number for MELSEC data link functions (the mdControl function
and the mdTypeRead function)
Network numbers and station numbers to be specified to the mdControl function or the mdTypeRead function are as follows:
Communication
Bus interface
CC-Link IE Controller Network
CC-Link IE Field Network
CC-Link IE TSN
MELSECNET/H network
CC-Link
*1 Station number setting for a CC-Link IE Controller Network module, CC-Link IE Field Network module, MELSECNET/H network module,
and CC-Link IE TSN module
Upper
Upper/
Setting item
lower
Upper
Network number
Lower
Station number
Method for specifying a logical station number
Set '0' in the upper byte (network number) of the station number above, and specify a logical station number in the lower byte (station number).
The setting range of the logical station number is 65 (41H) to 239 (EFH).
Logical station numbers can be set in the target setting of a network module. For parameters of a network module, set them in CW Configurator. (CW
Configurator Operating Manual)
⋅ [Navigation window]  [Parameter]  [Module Information]  a target module  [Application Settings]  [Target settings]
*2 When '0 (0H)' or '125 (7DH)' is specified for the station number, a specified control station of the network, which is specified for the
network number, is accessed. To access the current control station (a station that is actually operating as the control station), specify the
station number from 1 (1H) to 120 (78H).
*3 When '0 (0H)' or '125 (7DH)' is specified for the station number, a specified control station of the network, which is specified for the
network number, is accessed. For CC-Link IE Field Network, to access a master operating station (a station that is operating as the
master station when the submaster function is used), specify the station number from 1 (1H) to 120 (78H).
Station number specification method
Own station: 255 (FFH)
Other station: 1 (CPU No.1), 2 (CPU No.2), 3 (CPU No.3), 4 (CPU No.4)
Own station: 255 (FFH)
*1,*2,*6
Other station:
Own station: 255 (FFH)
*1,*3,*6
Other station:
Own station: 255 (FFH)
*1,*3,*6
Other station:
Own station: 255 (FFH)
*1,*2,*6
Other station:
Own station: 255 (FFH)
Other station: 0 (0H) to 63 (3FH), 65 (41H) to 239 (EFH)
Lower
Setting value
Description
1 (1H) to 239 (EFH)
Set this to specify other stations in the own network or each station on other networks.
• Set this to issue a sending request to any of CC-Link IE Field Network, CC-Link IE
Controller Network, CC-Link IE TSN, MELSECNET/H network, or MELSECNET/10
network.
1 (1H) to 120 (78H)
Set the station number of other stations.
• For MELSECNET/H network, the setting range is from 1 to 64.
• For CC-Link IE Field Network, CC-Link IE Controller Network, or CC-Link IE TSN, the
setting range is from 0 to 120.
0 (0H), 125 (7DH)
• For MELSECNET/H network and CC-Link IE Controller Network, the access target is a
control station.
• For CC-Link IE TSN and CC-Link IE Field Network, the access target is a master station.
*6
*4,*5,*6
*2
1.3 MELSEC Data Link Functions
*3
1 COMMON ITEMS
47
1