Network number and station number
Network number and station number for MELSEC data link functions (excluding the
mdControl function and the mdTypeRead function)
Network numbers and station numbers to be specified to MELSEC data link functions are as follows:
To specify station numbers for the mdControl function and mdTypeRead function, refer to "Network number and station
number for MELSEC data link functions (the mdControl function and the mdTypeRead function)".
Communication
Specification method
Bus interface
Own station
Other station
CC-Link IE Controller
Own station
Network
Other station
Logical station number
CC-Link IE Field
Own station
Network
Other station
Logical station number
CC-Link IE TSN
Own station
Other station
Logical station number
MELSECNET/H
Own station
network
Other station
Logical station number
CC-Link
Other station
Logical station number
*1 Logical station numbers are logical numbers which specifies "station number" in a user program (MELSEC data link functions).
Logical station numbers are used to access from an applicable module (channel number) to the other station CPU (other CPU of a
multiple CPU system). However, if the access target CPU module is not compatible with a network module on the access route, an error
will occur and the applicable module will not be able to access to the CPU module.
To access directly to a CPU module which controls other stations on MELSECNET/10 network, MELSECNET/H network, CC-Link IE
Controller Network, CC-Link IE Field Network, and CC-Link IE TSN, the logical station number is not required to be set. Use the station
numbers of other stations on MELSECNET/10 network, MELSECNET/H network, CC-Link IE Controller Network, CC-Link IE Field
Network and CC-Link IE TSN.
Also, for direct access to CC-Link other stations (station number 0 to 63) or the CPU module which controls CC-Link other stations,
setting of the logical station number is not required. Specify or use the station number of CC-Link.
Logical station numbers can be set in the target setting of a network module. For parameters of a network module, set them in CW
Configurator. (CW Configurator Operating Manual)
⋅ [Navigation window]  [Parameter]  [Module Information]  a target module  [Application Settings]  [Target settings]
*2 The station number 64 cannot be specified for CC-Link communication.
*3 Communication to C Controller module (own station) by using the MELSEC data link functions is possible; however, it may take longer
to execute the functions compared to the C Controller module dedicated functions. Use the C Controller module dedicated functions to
create a user program in which performance should be ensured (such as control program).
*4 The group number and all stations specification is valid when the SEND function (mdSendEX (message send function)) with 'no arrival
confirmation' specification is used.
*5 The group number can be specified when using CC-Link IE Controller Network, MELSECNET/H network, and CC-Link IE TSN.
*6 When '0 (0H)' or '125 (7DH)' is specified for the station number, a master station of the network, which is specified for the network
number, is accessed. To access a master operating station (a station that is operating as the master station when the submaster function
is used), specify the station number from 1 (1H) to 120 (78H).
Network number
0 (0H)
0 (0H)
Station number
1 (1H) to 239 (EFH)
*4,*5
Group number 1 to 32
*4
All stations
*1
0 (0H)
0 (0H)
Station number
1 (1H) to 239 (EFH)
*4
All stations
*1
0 (0H)
0 (0H)
Station number
1 (1H) to 239 (EFH)
*4,*5
Group number 1 to 32
*4
All stations
*1
0 (0H)
0 (0H)
Station number
1 (1H) to 239 (EFH)
*4,*5
Group number 1 to 32
*4
All stations
*1
0 (0H)
0 (0H)
*1
Station number
*3
255 (FFH)
1 (CPU No.1), 2 (CPU No.2), 3 (CPU No.3),
and 4 (CPU No.4)
255 (FFH)
1 (1H) to 120 (78H)
*7
*7
0 (0H)
, 125 (7DH)
129 (81H) to 160 (A0H)
240 (F0H)
65 (41H) to 239 (EFH)
255 (FFH)
*6
0 (0H) to 120 (78H), 125 (7DH)
240 (F0H)
65 (41H) to 239 (EFH)
255 (FFH)
1 (1H) to 120 (78H)
*8
*8
0 (0H)
, 125 (7DH)
129 (81H) to 160 (A0H)
240 (F0H)
65 (41H) to 239 (EFH)
255 (FFH)
1 (1H) to 64 (40H)
*7
*7
0 (0H)
, 125 (7DH)
129 (81H) to 160 (A0H)
240 (F0H)
65 (41H) to 239 (EFH)
*2
0 (0H) to 63 (3FH)
65 (41H) to 239 (EFH)
1 COMMON ITEMS
1.3 MELSEC Data Link Functions