Vinotemp WM-1500HTD Use & Care Manual page 11

Cooling unit
Hide thumbs Also See for WM-1500HTD:
Table of Contents

Advertisement

2. Push and immediately release the SET key or wait for 5 seconds to display the
probe value again.
3.2 How to change the set-point
1. Push the SET key for more than 3 seconds to change the Set point value;
2. The value of the set point will be displayed and the "°C" or "°F" LED starts
blinking;
3. To change the Set value, push the keys
or
arrows within 10s.
4. To memorize the new set point value, push the SET key again or wait 10s.
4) Humidity Adjustment
The parameter Fon is used to modulate the humidity in the wine cabinet. The
higher value of Fon, the higher relative humidity will be.
1. Press the Set +
keys for 3 sec. (the "°C" or "°F" LED starts blinking).
2. Release the keys, then push again the Set +
keys for more than 7sec, the
Pr2 label will be displayed immediately followed from the HY parameter.
3. Select the required parameter Fon by up or down keys
.
4. Press the "SET" key to display its value.
5. Use up or down keys
to change its value.
6. The default value is 5, change high or low value to maintain high or low
humidity.
7. Press "SET" to store the new value.
8. To exit: Press SET +
or wait 15sec without pressing a key.
5) Manual Defrost
Push the DEF key for more than 2 seconds and a manual defrost will start.