  • Page 1 VSP3041 INSTRUCTIONS VSP INSPECTION SYSTEM...
  • Page 2: Table Of Contents

    Only use the device for the visualization of objects. To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec. Any use other than the intended use is regarded as misuse.
  • Page 3 Charge lithium-ion modifications, alterations or structural changes batteries in due time before they are discharged to the device are forbidden. completely. Risk of injury due to electrical voltage. Damage to the device may occur. VSP inspection system VSP3041...
  • Page 4: Information About The Device

    VSP‑R30 and modularly also to the mobile control unit VSP Control. The supplied camera head can be exchanged for other optional Trotec camera heads. The camera's functions can be controlled via the mobile control unit VSP Control. Using the provided snap-in system, the mobile control unit can be affixed to the rear of the supplied push-cable drum.
  • Page 5 Display Audio connection SD card slot Standoff for snap-in attachment to the push-cable drum Battery attachment screw Fold-out stand Battery Battery level indication Battery test button Multi-connector socket with protective cap Power adapter connection HDMI port USB connection VSP inspection system VSP3041...
  • Page 6 Indicates whether the memory Video button For starting / stopping a video indication card is activated recording Date indication Indicates the current date Photo button For taking a photo Battery status Indicates the charge status of the indication battery VSP inspection system VSP3041...
  • Page 7 Transmitter VSP3041 Transmission 512 Hz frequency Frequency modulation Max. transmission 45 mW power Range 5 m* Dimensions length 66.8 mm, ø 21 mm *The range may vary depending on the receiver and the surface/material to be penetrated. VSP inspection system VSP3041...
  • Page 8: Transport And Storage

    • For storing the device, use the transport case included in the scope of delivery in order to protect the device from external influences. • the storage temperature complies with the values specified in the Technical data • Battery/Batteries removed during prolonged storage VSP inspection system VSP3041...
  • Page 9: Operation

    4. In order to detach the VSP Control, first press it against the push-cable drum, then upwards. Make sure that the plug is located on the display side and does not dangle at the rear of the VSP Control. VSP inspection system VSP3041...
  • Page 10 You can connect the supplied camera head (or one of the Note optional camera heads from Trotec) to the end of the push- The push cable of the VSP-R30 push-cable drum is cable drum VSP‑R30. Please proceed as follows to connect the tensioned and can unwind unexpectedly.
  • Page 11 ð If the camera is connected, the current recordings are displayed in the live image mode. 2. Press the Power button (42) for approx. 2 seconds to switch the device off again. ð A melody sounds and the device switches off after a few seconds. VSP inspection system VSP3041...
  • Page 12 Using the metre counter Recording a video 1. Press the Video button (45). The metre counter of the VSP inspection system VSP3041 can ð The video recording is started. display the number of metres the push cable has been unreeled ð A recording symbol and the recording duration appear based on the position 0.0.
  • Page 13 You can use the VSP Control unit with an optionally available Plus brightness For increasing the illumination radio transmitter from Trotec. It transmits the position of the button intensity at the camera head camera head at the end of the push cable to a receiver, e.g. the...
  • Page 14 You can use the control unit VSP Control with various video the camera head back on. endoscope probes optionally available from Trotec. To use an 7. Press the Photo button on the borescope (70) or on the optional video endoscope, please proceed as follows: VSP Control unit (46) to take a photo.
  • Page 15: Software

    1. Navigate to the Screen contrast setting. 2. Set the desired contrast using the Left (38) and Right (37) arrow buttons, or shift the slider on the display to the desired position with your finger. ð The setting is applied immediately. VSP inspection system VSP3041...
  • Page 16 ð The display is rotated by 180°. Right (37) arrow buttons, or shift the slider on the display ð The rotation status is shown on the display (58). to the desired position with your finger. ð The setting is applied immediately. VSP inspection system VSP3041...
  • Page 17 5. Navigate to the Volume setting. 6. Set the desired volume setting using the Left (38) and Right (37) arrow buttons, or shift the slider on the display to the desired position with your finger. ð The setting is applied immediately. VSP inspection system VSP3041...
  • Page 18 4. Press the Confirm button (43) or tap the setting on the 4. Press the Cancel button (84) to cancel the process. display again. ð The setting is applied immediately. ð The device switches off automatically after the set time if no input is detected. VSP inspection system VSP3041...
  • Page 19: Errors And Faults

    This is normal and does not affect its functioning. Info You can supply the device with electricity via the power adapter. To do this, connect the cable of the supplied power adapter to the power adapter connector (29). VSP inspection system VSP3041...
  • Page 20: Disposal

    Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean water to moisten the cloth. Repair Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer. VSP inspection system VSP3041...
  • Page 21 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...