Trotec SL400 Operating Manual

Trotec SL400 Operating Manual

Digital sound level meter
Hide thumbs Also See for SL400:

Advertisement

Quick Links

SL400
EN
OPERATING MANUAL
DIGITAL SOUND LEVEL METER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec SL400

  • Page 1 SL400 OPERATING MANUAL DIGITAL SOUND LEVEL METER...
  • Page 2: Table Of Contents

    • Do not expose the device to directly squirting water. • Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts. digital sound level meter SL400...
  • Page 3 To use the device for its intended use, only use accessories and penetrating the housing! spare parts which have been approved by Trotec. Do not immerse the device and the accessories in water. Make sure that no water or other liquids can Foreseeable misuse enter the housing.
  • Page 4: Information About The Device

    Power button Device depiction MAX/MIN button A/C button F/S button LEVEL button SETUP button REC button HOLD button Button for background illumination Designation Measuring probe with protective cap Tripod thread Battery compartment with cover Power button Control panel Display digital sound level meter SL400...
  • Page 5 Measurement value display AUTO indication HOLD indication dBA / dBC indication FULL indication (memory full) REC indication Battery status indication Automatic switch-off indication DATE indication Time / date display Indication of the scale's minimum value MAX indication digital sound level meter SL400...
  • Page 6: Transport And Storage

    • 1 x Mini tripod • 1 x CD with software • 1 x USB cable • 1 x Mini screwdriver • 1 x 9 V battery • 1 x Power adapter • 1 x Quick guide digital sound level meter SL400...
  • Page 7: Operation

    3. Press the MAX/MIN button (7) again to quit using the MAX/ and the sound source, unless their influence on the MIN function. sound intensity is to be measured on purpose as well. digital sound level meter SL400...
  • Page 8 16. In order to return to the menu for setting time and date, automatic switch-off function. press the SETUP button (11) when rSt is displayed. ð The next setting corresponds to the menu for adjusting the current date as described in step 3. digital sound level meter SL400...
  • Page 9: Errors And Faults

    Trotec assumes no liability with regard to this ð The new saving interval is saved until the device is free software and also provides no support on that score. Trotec switched off. accepts no liability concerning the use of this free software and...
  • Page 10: Maintenance And Repair

    A recalibration requires special tools. In the case of a administration. You can also find out about other return options recalibration please contact the Trotec service. that apply for many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an...
  • Page 11 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...