Biddle STYLE2 Series Installation Operation & Maintenance

Biddle STYLE2 Series Installation Operation & Maintenance

Hide thumbs Also See for STYLE2 Series:

Advertisement

Quick Links

INVISIDOR STYLE
AIR CURTAIN
2
INSTALLATION, OPERATION &
MAINTENANCE ORIGINAL
INSTRUCTIONS
LANGUAGE: ENGLISH
Version 5.0 (Original Manual)
Page | 1

Advertisement

Table of Contents
loading

Summary of Contents for Biddle STYLE2 Series

  • Page 1 INVISIDOR STYLE AIR CURTAIN INSTALLATION, OPERATION & MAINTENANCE ORIGINAL INSTRUCTIONS LANGUAGE: ENGLISH Version 5.0 (Original Manual) Page | 1...
  • Page 2: Warranty

    AIR CURTAIN: Installation, Operation & Maintenance Instructions COPYRIGHT All the information and drawings in this manual are the property of Biddle and may not be used (other than for the actual operation of the device), photocopied, duplicated, translated and/or be brought to the attention of third parties without Biddle’s prior written permission.
  • Page 3: About This Manual

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions ABOUT THIS MANUAL This manual describes the installation, operation and maintenance of the Invisidor Style air curtain unit. The manual also provides information on service and fault conditions. IMPORTANT INFORMATION Electrical Supply and Wiring to the Air Curtain All electrical wiring and connections MUST be carried out by a competent qualified electrician in accordance with the latest edition of national and local wiring regulations and/or local statutory regulations.
  • Page 4: Delivery Contents

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions DELIVERY CONTENTS The following items are supplied in the box at delivery. Any missing or damaged parts should be reported to the place of purchase: • Invisidor Style Air Curtain • Touchpad Remote Control Supplied with 6m RJ Control Cable) •...
  • Page 5: Technical Data Table

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions TECHNICAL DATA TABLE Rated Current Electrical Heat Power Weight Air Curtain Supply Output Input phase (kg) (V/ph/Hz) (kW) (kW) Ambient Units Style 100A H 230/1/50 0.30 Style 150A H, Style 150A V 230/1/50 0.40 Style...
  • Page 6: Installation

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Unit Operation Conditions IP Rating IP20 C – 60 Maximum Temperature (Storage) Maximum Temperature (Operating – Heating Models) C – 30 Maximum Temperature (Operating – Ambient Models) C – 40 Relative Humidity 95% Non-Condensing INSTALLATION Horizontal Style...
  • Page 7 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Wall and Ceiling Fixing Before fitting the unit to the wall or ceiling ensure suitable wall fixing bolts are used, taking into account unit weight (see Table 1)*. Style horizontal air curtains are supplied with two steel wall or ceiling brackets fitted to each end of the unit.
  • Page 8 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions ALWAYS NEVER ▪ ▪ Ensure lifting operations are planned, Allow inexperienced personnel to operate supervised and carried out in a safe lifting equipment. manner. ▪ Use damaged accessories or equipment. ▪ Ensure lifting equipment...
  • Page 9 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Version 5.0 (Original Manual) Page | 9...
  • Page 10 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Version 5.0 (Original Manual) Page | 10...
  • Page 11 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Version 5.0 (Original Manual) Page | 11...
  • Page 12 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Vertical Style Air Curtain The air curtain must be surface mounted within the building and not exposed to the external environment or moist conditions. Do not install the air curtain in a doorway situation where there is a likelihood, or there has been a history of, rain ingress.
  • Page 13 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Back of foot plate Using a hacksaw carefully cut the projecting bolts flush with the nut, ensuring the foot plate is not damaged or marked in any way. Remove only one M10 nut and refit and secure bolt with a stainless steel M10 dome nut supplied. Repeat for each of the other three projecting bolts one at a time.
  • Page 14 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions LPHW Models For LPHW models ensure suitable water isolating valves, as detailed below, are fitted to both the flow and return pipework. For the Style air curtain the 3 port valve is fitted inside each unit. There must be a removable section of pipe between the isolating valve in the flow pipe and the inlet into the 3-port valve, to allow for removal of the 3 port valve if it ever needs to be replaced.
  • Page 15 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Each Style LPHW air curtain is fitted with the 3 port valve inside the casing of the air curtain. For two air curtains in a stack each air curtain requires its own separate water flow and return connection. In order to obtain optimum heat output, all air from the system and the heating coil must be vented.
  • Page 16 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Version 5.0 (Original Manual) Page | 16...
  • Page 17: Wall Mounting

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions MOUNTING AND CONNECTING CONTROLLER Mount the Touch Controller in a convenient position directly to the wall or onto a switch box. Wall Mounting Step 1 Press release button on side of Controller case and pull the back case away. Figure 7.
  • Page 18: Using The System

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions USING THE SYSTEM Basic (Wall Controller) Operation The air curtain can be operated using the wall controller. The wall controller must be connected via RJ communications lead to CCS PCB. Home Speed Up Down On/Off Press and hold Home touchpad for 2 seconds to turn air curtain ON or OFF.
  • Page 19: Wifi Operation

    Setting up Wifi connectivity 1. Download and install the Biddle air curtain app from the Apple App Store or Google Play Store 2. Follow on screen instructions to link the device to your app.
  • Page 20: Remote Control Settings

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Remote control Settings Touch Controller with four default software Flag settings provide optional features detailed in Table 2. If required, software Flag values can be changed by entering advanced settings as below. With Controller ON, long press both Up and Down touchpad –...
  • Page 21: External Controls

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions EXTERNAL CONTROLS Remote switch contacts IN0, IN1 Figure 9 Terminals IN0 and IN1 on the CCS PCB inside the air curtain can be used to provide different control strategies using remote volt-free contacts (see Fig 9). This could be to provide remote On/Off from a timer or BMS Digital/Output contact, to work with a door switch or for simple weather compensation control to disable heating when outdoor air temperatures become warmer.
  • Page 22 The Controller must stay plugged-in for the air curtain to keep working. An optional plug-in EEPROM is available from Biddle so the Remote Control can be un- plugged and the air curtain stay working. Visit the Biddle website for details.
  • Page 23: Multiple Air Curtain Systems

    NOTE: To promote increased energy saving a more advanced weather compensation control strategy is available from Biddle. Using a heating curve, the discharge air temperature of the airstream coming from the air curtain is controlled against the outside air temperature. Visit the Biddle website for details. MULTIPLE AIR CURTAIN SYSTEMS...
  • Page 24: System Configuration

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions SYSTEM CONFIGURATION Optional features WARNING: Isolate and disconnect air curtain from the power source before making any changes. DIP switches on the air curtain CCS PCB (see Fig 13) provide the following optional features, as explained below: •...
  • Page 25 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions NOTE: A range of advanced factory fitted and plug-in control options are available from Biddle to enhance the performance of the CCS PCB inside the air curtain. These include advanced weather compensation ®...
  • Page 26: Commissioning The System

    INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions COMMISSIONING THE SYSTEM Verify System Operation To commission the system, verify the following conditions are met: • With the casing still removed check the air curtain fans operate correctly and there is no excessive mechanical noise.
  • Page 27 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Instruct customer and hand over Before leaving site, hand over the installation to the customer/end user or their representative. Explain that any person operating the air curtain must be given supervision and instruction by the person responsible for their safety, concerning the safe use of the unit and to understand any hazards involved.
  • Page 28 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions FAULT CONDITIONS Touch Controller Reset Overheat Safety cut-out This is indicated by flashing warning symbol on Touch Controller and a red status LED on the CCS PCB inside the air curtain. To reset a overheat safety cut-out: Step 1 Switch off the electrical supply to the air curtain.
  • Page 29: Service And Maintenance

    The following servicing and maintenance must be carried out by a competent electrician WARNING: or a Biddle appointed technician. Always disconnect and isolate the mains electrical supply before installing, maintaining or repairing this equipment. With 2.5m or 3m vertical air curtains there are two air curtains, one stacked on top of the other.
  • Page 30 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions To Slave Master/Slave Cable Air Curtain 85 deg C Auto Thermal Trip REMOTE 7-way Plug CONTROL IN1 IN0 EEPROM F1 (F100mA) F2 (T6.3A) Black rectangle is F2 F1 moveable head of DIP switch High speed Med speed...
  • Page 31 INVISIDOR STYLE AIR CURTAIN: Installation, Operation & Maintenance Instructions Fan 2 Fan 1 Version 5.0 (Original Manual) Page | 31...