MAG SWITCH 240V
NHD MS1-09D2I7N112PBVO
A1
1L1
3L2
Contactor
NHD
C09D10I7
240V
2T1
4T2
11
8
10
OL Relay
9
NHD NTH-11 2PE
98
97
96
2T1
4T2
Model G0966 (Mfd. Since 04/23)
Wiring Diagram 240V
A2
5L3
13NO
17
NHD
1PS
18
GND
6T3
14NO
A2
O
R
95
6T3
Ground
G
Hot
240
VAC
Hot
6-15 Plug
(As Recommended)
MOTOR 120V/240V
1
4
1
2
3
Start
Capacitor
300MFD
125VAC
Rewired 240V
READ ELECTRICAL SAFETY
ON PAGE 35!
Ground
Run
Capacitor
40uF
250VAC
-37-