UL2586 (rated temperature:
105℃) 4Ex12AWG, 2Cx18AWG
Power cable: 12AWG (3.31
Cable specifications
mm
Brake cable: 18AWG (0.823
mm
12.2±0.4 mm (main circuit)
Sheath diameter
Internal structure and
conductor colors
Fill in "X.X" in the model number with cable length.
3.2.1.4
Power Cable Shield
Take proper shielding measures in the following locations to prevent equipment
damage:
Locations with interference caused by static electricity
●
Locations with strong electric field or magnetic field
●
Locations with radioactive rays
●
3.2.2
Motor Cable
3.2.2.1
Rules
Danger
Do not connect the output terminals U, V, and W of the drive to a three‑phase
●
power supply. Failure to comply may result in physical injury or a fire.
Do not connect the motor terminals U, V, and W to a mains power supply. Failure
●
to comply may result in physical injury or a fire.
The main circuit cable must be away from the motor so that its insulation will not
●
be damaged by high temperature of the motor surface.
Connect the servo drive to the motor directly. Do not use an electromagnetic
●
contactor during wiring. Failure to comply may result in equipment fault.
MS1H3 29C–75C (Applicable to 2.9 kW–7.5 kW)
2
) OD of insulation: 4.1 mm
2
) OD of insulation: 2.0 mm
UL2586 (rated temperature:
105℃) 4Ex12AWG, 2Cx18AWG
Power cable: 12AWG (3.31
2
mm
) OD of insulation: 4.2 mm
Brake cable: 18AWG (0.823
2
mm
) OD of insulation: 2.15
mm
12.5±0.4 mm (main circuit)
‑33‑
Electrical Design Guide
UL2586 (rated temperature:
105℃) 4Ex12AWG, 2Cx18AWG
Power cable: 12AWG (3.31
2
mm
) OD of insulation: 4.2 mm
Brake cable: 18AWG (0.823
2
mm
) OD of insulation: 2.15
mm
13.2±0.4 mm (main circuit)