Cable Preparation - Inovance SV670P Series Installation Manual

Hide thumbs Also See for SV670P Series:
Table of Contents

Advertisement

AC Input Reactor
EMC filter
Install the filter near the input terminals of the drive. The cable between the filter and
the drive must be shorter than 30 cm. Connect the grounding terminal of the filter
together with the grounding terminal of the drive. Ensure the filter and the drive are
installed onto the same conductive mounting surface that is connected to the main
grounding of the control cabinet.
3.5

Cable Preparation

There are many cables connecting to the drive, including the power supply cable,
power cable, encoder cable, control cable and communication cable. For detailed
cable specifications, see the hardware guide.
If you have special requirements on the cables, contact Inovance.
Crimping
The following figure illustrates how to crimp a cable. The crimping method may vary
with different cable types.
Figure 3‑9 Installing the AC input reactor
‑19‑