Inovance SV670P Series Maintenance Manual

Inovance SV670P Series Maintenance Manual

Hide thumbs Also See for SV670P Series:

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Inovance SV670P Series

  • Page 2: Preface

    Introduction Thank you for purchasing the SV670P series servo drive developed by Inovance. The SV670P series servo drive is a high‑end servo drive designed based on global‑ leading standards and high‑end application needs. It is featured with high speed, high precision, high performance, and tuning‑free Function.
  • Page 3 Provides instructions on maintenance SV670P Series Servo Drive 19011870 and repair of the equipment. Maintenance Guide Presents the safety function and related SV670P Series Servo Drive Safety certifications and standards, wiring, 19011867 Guide commissioning process, troubleshooting, and functions. Provides information on selection,...
  • Page 4: Table Of Contents

    Table of Contents T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Preface ................1 1 Daily Maintenance and Repair .
  • Page 5: Daily Maintenance And Repair

    Daily Maintenance and Repair Daily Maintenance and Repair Routine Maintenance Items Standard operating conditions: Average annual ambient temperature: 30℃ Average load rate: < 80% Daily operating time: < 20 h 1.1.1 Routine Checklist Check the following items during routine inspection. Table 1–1 Routine checklist Routine Checklist Checked...
  • Page 6: Periodic Inspection Items

    To keep the servo drive and servo motor in good condition, perform parts replacement based on the replacement cycles listed in the following table. Contact Inovance or Inovance agent before replacement to double check whether the part needs to be replaced.
  • Page 7 Daily Maintenance and Repair Type Object Standard Replacement Interval Remarks About 8 years (ambient Power bus temperature: 30°C; load rate: capacitor 80%; uptime per day: 20 hours; standard environment 5 years (ambient temperature: 30°C; load rate: 80%; uptime per day: 20 hours; standard environment Control circuit About 10 years (ambient...
  • Page 8: Replacement Of Parts

    Replacement of Parts Replacement of Parts Replacing the Motor Flat Key Observe all the requirements presented in this chapter. Failure to comply may ● result in equipment fault or damage. Violent disassembly is not allowed. Take enough care during disassembly to ●...
  • Page 9: Removing The Motor Oil Seal

    Replacement of Parts Removing the Motor Oil Seal Tools needed: a pair of needle‑nose pliers, a pair of slip‑proof gloves, and a piece ● of cotton cloth. Disassembly procedure: ● 1. Put the cotton cloth onto the supporting point B to avoid the end cover from being scratched during disassembly.
  • Page 10 Back cover *19011870A01* ‑9‑...

Table of Contents