Installing The Louver (Optional) - ICE AIR RSNU Installation Manual

Packaged terminal air conditioner (ptac) unit for new construction
Table of Contents

Advertisement

Installing the Louver
(Optional)
The louver directs condenser airflow and
provides a protective barrier for the
outdoor coil.
3.946"
.438"
B
Notes:
Components, parts and
dimensions shown may vary
depending on options and type
of installation.
Threaded studs must be
slidable about 2" up and down
Due to Ice Air's ongoing product development programs, the information in this document is subject to change without notice.
NOTE: THREADED STUDS MUST BE SLIDABLE ABOUT 2" UP AND DOWN
IMPORTANT: Depending on the size and
style of the louver chosen, you should
determine whether it can be installed before
or after the sleeve installation.
1. Install four threaded studs into threaded
openings on the inside face of the louver.
2. Install a washer and one hex nut to the
end of each stud.
3. Manipulate the louver out through rear
wall sleeve opening. Keep a firm grip on
louver to prevent causing possible injury
or property damage.
25.000"
SECTION B-B
41.642"
FRONT VIEW
SLEEVE
INTERNAL
ANGLE ( 2 )
WASHERS & NUTS
( 4 EACH )
4 SS PINS 10-24 x 1"
1.125"
B
.775" (TYP)
OPTIONAL SUPPORT
ANGLE
9
4. Attach the louver to the wall sleeve
by aligning and inserting the hex nut
threaded onto the studs through the
holes in the wall sleeve.
5. Secure the louver to the wall sleeve by
tightening the hex nut and adding and
tightening an additional hex nut.
3.346"
ISOMETRIC VIEW
15.971"
8.500"
RIGHT VIEW
LOUVER
THREADED
STUDS ( 4 )