K. Central Station Programming
The standard 1600A emergency phone is capable of communicating using the "Ademco Contact I.D.", "Ademco High
Speed", "DTMF 4+1 Express", or the "DTMF 4+2 Express" formats. All formats use the programming memory location
#20 to store the account code and alarm details.
1. Central Station Programming Features
a. Accessing the Programming Mode
Before programming, you must access the programming mode (see Programming section A).
b. Enabling/Disabling Central Station Mode
The 1600A Series emergency phone can be placed in the "Central Station Mode" by entering a central station
phone number in position #05 while programming. To cancel the "Central Station Mode," clear position #05 by
entering #05 only (see Programming section D).
To Program the 1600A Series Phone...
...to enable central station programming and dial 952-2567
...to disable central station programming
c. Ring No Answer
When the 1600A Series emergency phone is in the "Central Station Mode", it is best to have the ring no answer
set to a minimum of three, because some receivers send a long tone after answering the line that sounds like
a ring back. If the 1600A is set to a ring no answer of two, the phone will disconnect (see Programming
section F).
d. Speed Dial Numbers
The 1600A Series phone can be programmed to dial a central station receiver only, or dial up to 5 voice num-
bers first, and if no answer, then dial the central station receiver. When calling the first numbers (memory posi-
tions #00-#04 (see Programming section D), the phone stays in "two-way talk mode" allowing two-way con-
versation. When calling the Central Station number (memory position #05), the phone is in a "listen only mode"
in order to interpret the hand shake signals of the receiver.
A second central station number position has been provided in
location #06 that is used when the central station receiver does
not have a talk over mode. If a number is placed in position
#05 and position #06 is cleared, the E-1600A will call the cen-
tral station monitor receiver. One or two alarm messages can
be sent to the receiver (see Operation section B, note 3). After
the receiver sends a kiss-off, the E-1600A lights the "Call
Connected" LED and goes into two-way talk mode. If numbers
are in both positions #05 and #06, the E-1600A will call the
receiver first, and after the kiss-off, will hang-up and redial the
number in position #06 for two-way voice communication
If only a central station is to be dialed, the central sta-
tion phone number must be preprogrammed in memory loca-
tion
and memory locations
Enter Programming
Enter Programming
must be cleared.
Step 2 - Enter Digits:
Step 1:
9 5 2 2 5 6 7 # 0 5
Location
Call Type
#00
Voice - Emergency
#01
Voice - Emergency
#02
Voice - Emergency
#03
Voice - Emergency
#04
Voice - Emergency
#05
Central Station Receiver
#06
Central Station Voice Line
#07
Voice - "Info" (E-1600-20A/52A only)
#08
Voice - "Info" (E-1600-20A/52A only)
#09
Voice - "Info" (E-1600-20A/52A only)
# 0 5