Viking E-1600A-BLT-EWP Technical Practice page 7

Ada compliant emergency tower phone with strobe
Hide thumbs Also See for E-1600A-BLT-EWP:
Table of Contents

Advertisement

Setting C - Silence Time Out
This feature selects the length of time that calls will remain connected without voice activ-
ity. Programmable in increments of 10 seconds up to a maximum of 90 seconds (Touch
Tones 1 - 9). To disable the silence time out, program 0 in this location. Use chart at the
far right. *
Setting D - Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the 1600A series
phone will dial the next programmed speed dial number, and con-
tinue to cycle through the emergency numbers until a call is com-
pleted.
This feature is disabled in the factory default setting.
Setting E - Dial Next Number on Busy
If enabled and a busy is detected, the 1600A series phone will dial the next pro-
grammed speed dial number, and continue to cycle through the emergency num-
bers until a call is completed. *
default setting. If the busy signal is interrupted with a promotional message, con-
tact your central office to have it removed.
Setting F - Pulse Dialing Rate (Pulses per second)
The 1600A series phone is capable of different pulse dialing speeds.
*
The factory default setting is 10pps.
G. Voice Announcer/Miscellaneous Options
The 1600A series phones have a built-in non-volatile digital voice announcer that may be used to identify the location
of the emergency phone call. The 16 seconds of digital record time is recorded remotely from a Touch Tone phone.
Programming options are as follows:
Factory Default Setting: 0 + 0 + 0 + 2 + 1 + 0
Two Digit Announcement Delay {
Repeat Announcement Setting
Hang-up on Return to Dial Tone
Panasonic Mode
Future Use (enter "0")
Settings A and B - Announcement Delay
The 1600A series phone is factory set to automatically start playing the
voice announcement after it has determined the call has been answered.
Alternately, the announcement may be programmed to play after a pro-
grammed amount of time, from 1 to 99 seconds after dialing.
If the announcement delay time is used, you must allow enough time for the
ring-no-answer and busy signals when using the redial features. The factory default is set to play automatically.
The factory default is 40 seconds.
This feature is disabled in the factory
Dial: A + B + C + D + E + F + # + 1 + 7
Touch Tone
1 or 0
2, 3, 4...9
(memory location #17)
Touch
Tone
0
1
2
3
4
5
6
7
8
9
Setting D
Disabled*
Dials second number after
2, 3, 4...9 rings respectively
Touch Tone
Setting E
1
Disabled*
2
Enabled
Touch Tone
Setting F
10 pps*
1
2
20 pps
Enter Settings Here:
A
B
C
D
E
F
0 #17
Touch Tone
Setting A/B
00
Play automatically
01-99
1-99 seconds*
series phone to detect
Silence
Time Out
Disabled
10 sec
20 sec
30 sec
40 sec*
50 sec
60 sec
70 sec
80 sec
90 sec
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-1600a-blt2-ewpPb-100Tbb-1

Table of Contents