2. Central Station Formats
The following examples explain the receiver formats and how to properly program memory location #20. Each for-
mat starts with a four digit account code. This is the code that is assigned by your central station for billing purpos-
es. You must access the programming mode before programming these features (see Programming section A).
If a number is shown, you must use that number. If an " " is shown, use any appropriate number.
A second information alarm message can be sent to the receiver, for any receiver that requires two separ-
rate messages. The second alarm message is programmed in
second alarm mesage, see
a. Ademco Contact ID Format
This DTMF format consists of a four digit account code, two digit message type, and a nine digit data field.
Enter Contact ID Settings Here:
b. Ademco High Speed Format
This DTMF format consists of a four digit account code, eight zone codes and one alarm type digit. With this
format you can identify up to eight different phones by using a zone per phone. A "5" in a zone position means
no alarm. The following example shows an alarm from the third phone.
Enter Ademco High Speed ID Settings Here:
c. 4+1 Express Format
This DTMF format consists of a four digit account code, two digit message type, and a single digit event code.
d. 4+2 Express Format
This DTMF format consists of a four digit account code, two digit message type, and a two digit event code.
10
section .
XXXX 18 1 14000 XXX #20
Account Code
Message Type
New Event
XXXX 55 1 55555 7 #20
Account Code
Idle Zone
Account Code
Message Type
Enter 4+1 Express ID Settings Here:
XXXX 27 XX #20
Account Code
Message Type
Enter 4+2 Express ID Settings Here:
location. For additional information about the
18 1 14000
XXXX 17 X #20
Memory Location
Event Code
Memory Location
Event Code
Memory Location
Any number to identify phone
General Alarm
Memory Location
Normal Alarm
New Event
55 1 55555 7 #20
17
#20
27
#20
#20