BioLAB BCMI-505 Operation Manual

BioLAB BCMI-505 Operation Manual

Mini centrifuge

Advertisement

Operation
Manual
BCMI-505
Mini Centrifuge
Thank you for Choosing Biolab products. Please read the "Operating
Instructions" and "Warranty" before operating this unit to assure proper
operation.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BCMI-505 and is the answer not in the manual?

Questions and answers

Summary of Contents for BioLAB BCMI-505

  • Page 1 Operation Manual BCMI-505 Mini Centrifuge Thank you for Choosing Biolab products. Please read the “Operating Instructions” and “Warranty” before operating this unit to assure proper operation.
  • Page 2 Mini Centrifuge BCMI-505 Index 1. Introduction ..............03 2. Operation guide ..............03 3. Notice ................05 4. Maintenance ..............06 5. Specification ..............06 6. Failure analysis and trouble shooting .........06 www.biolabscientific.com...
  • Page 3 Mini Centrifuge BCMI-505 Introduction Tow types rotators are provided: 1) 8 x 1.5ml rotator (Suit for1.5ml/2.0ml x 8 tubes. Additional 0.2ml and 0.5ml tube suit. 0.2ml and 0.5ml tube are adapted with the tube suit.) 2) 2 x 8 x 0.2 ml rotator (Suit for 0.2ml x 8 PCR tubes, 2 ranks supplied.)
  • Page 4 Mini Centrifuge BCMI-505 2.2 Rotor Replacement 1. Pick up the rotor. 2. Install the rotor. Push the two sides of the clip Aim the middle hole of the rotor at towards middle (Refer to A1). Use the clip. Push until the rotor is another hand to pick up the rotor.
  • Page 5 Mini Centrifuge BCMI-505 c. Press or of time key to increase or decrease the timing value. Keep pressing make the value increase or decrease tens or hundreds times. d. Keep pressing and of timing key around 6 seconds to change time unit. The indicator light of Minute”...
  • Page 6 Mini Centrifuge BCMI-505 Maintenance Use mull with non-corrosive cleansing fluid (PH=7±1) to clean surface of the instrument. Operate the instrument after it dry out. Do not dip the instrument into fluid or water it. Specification Dimension: 175X155X118 (mm) Power: ≤45W Power Input: AC110/220V, 50/60Hz Fuse: 0.5A /1.0A...
  • Page 7 Mini Centrifuge BCMI-505 Noisy and Tube lid is not covered vibrate heavily Put same volume sample in each well, sample poured out when running tube and cover the lid well. when centrifuge working Rotor aged or partial Change the rotor...
  • Page 8 BIOLAB SCIENTIFIC LTD. 3660 Midland Avenue, Suite 300, Toronto, Ontario M1V 0B8 Canada Email: contact@biolabscientific.com Tel: +1 707 533 1445 Website: www.biolabscientific.com...