Intended Use; Limitations On Use; Approvals; Type-Identical Marking - Dräger FPS 7000 RP Instructions For Use Manual

Hide thumbs Also See for FPS 7000 RP:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
en
|

Use

The masks are module B type-tested and must not be modified.
All Dräger FPS 7000 RP have a wiper.
One Dräger FPS 7000 RP model is equipped with a drinking valve. A drinking
tube can be used to connect a CamelBak
FPS 7000 RP. However, this drinking reservoir is not suitable and approved for
firefighting.
Mask spectacles can be inserted for users who wear spectacles.
The facepieces can be used at temperatures from -30 °C to +60 °C.
3.3

Intended use

The Dräger FPS 7000 RP protect the face and eyes against aggressive media
and are approved for use with Dräger closed-circuit breathing apparatus.
3.4

Limitations on use

WARNING
Beards and sideburns in the sealing area of the full face mask will cause
leakages. Therefore, the full face mask should not be used by anyone with
facial hair of this sort. Earpieces in the sealing area also cause leakages.
► Use special mask spectacles.
3.5

Approvals

The full face masks are approved according to:
EN 136:1998 CL.3+
(EU) 2016/425
(EU) 2016/425 as brought into UK law and amended
The mask/helmet combinations are also approved according to:
DIN 58610:2014
Declaration of conformity: see www.draeger.com/product-certificates
12
®
hydration pack to the Dräger
Both versions meet the flame engulfment requirements stipulated in EN 137.
The full face masks and mask/helmet combinations combined with the
Dräger PSS BG 4 / PSS BG 4 plus / BG ProAir are approved according to
EN 145.
3.6

Type-identical marking

The facepieces are marked differently:
Front port
RP
Mask body
EPDM or Si,
EN 136:1998 CL.3+
CExxxx (notified body in Europe)
Mask body size
S (small), M (medium), L (large)
Inner mask size
1 (small), 2 (medium), 3 (large)
Visor
PCas or APECas (coated with scratch-resistant
material on both sides), F (fire brigade), according
to EN 166
A (ballistic protection class 190 m/s)
T (ballistic protection at extreme temperatures,
tested at -30...+60 °C with 190 m/s)
Head harness
EPDM, CR or Si, M/L or S
Hairnet
H
Mask/helmet adapter
S-fix (H61) or Q-fix (H62)
Drinking tube connector
TR
4
Use
4.1

Conditions for use

The mask/helmet combination needs to be carefully adapted to the equipment
wearer (correct mask size, fastening plate settings and internal helmet
components) due to its design.
Instructions for use
|
Dräger FPS 7000 RP

Advertisement

Table of Contents
loading