3. Packing list and installation

3.1 Packing list and accessories
The standard equipment consists of the following components. Open the package and check whether everything is in good condi-
tions. Keep the original package for some days, just in case.
Components
- Ventilated shelf
- Tray support
Handle for handing trays
-
- Water drainage tube
- Water filling hose
- Electrical mains connection cable
- Door gasket (spare part)
- User manual
3.2 Location
Place the machine on a flat, leveled surface, suitable for the equipment weight. Use the supplied leveller to level the autoclave.
Note: The autoclave should be slightly raised from the front side to ensure the water in the boiler not to accummulate back in the
drain area. Otherwise, the «drying» phase will be incorrect and may cause the error message E3.
You will need a plug, no longer than 1m, in accordance with the equipment features. There's no need of a water tap nor a drain.
To work comfortably, leave about 50cm around the equipment. To ensure air circulation, leave a free space about 20cm behind the
equipment. Be careful not to block any ventilation grid.
The sterilizer should be set in a place which at least has 10cm distance with each side (20cm of the top) and should be set in a
place with good ventilation.
The temperature of enviroment:
The humidity of environment:
Atmosphere pressure:
An earth connection is essential.
CAUTION: DO NOT PUT ANY STUFF WHICH EASILY MELTS NEAR THE STERILIZER.
- The sterilizer should be set on level table or place; the front-end should be a little bit higher then back-end.
- The sterilizer cooling and vent area should not be jammed or blocked.
- Do not put any stuff on the top of the sterilizer.
- Do not put any stuff in front of the door, to avoid accident when open the door.
- Do not put any corrosive stuff near the sterilizer to avoid accident or risk.
J
.P. SELECTA s.a.u.
CODIGO 80416 REV D
5-40ºC.
≤85%
860Hpa-1060Hpa
Autovía A-2 Km 585.1 Abrera 08630 (Barcelona) España
e-mail: selecta@jpselecta.es - website: http://www.grupo-selecta.com
Units
3
1
1
1
1
1
1
12/2023
Tel 34 937 700 877 Fax 34 937 702 362
Pag.: 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Autester st dry pv-b print 23l40017384001739

Table of Contents