Functional Description; Main Modules - Boyser AMP Series Operating Instructions Manual

Peristaltic pump
Table of Contents

Advertisement

3.

Functional description

The AMP Series is a positive displacement pump. The feed chemical is conveyed by the
rotor squeezing the hose in the direction of flow. No valves are needed for this. This ensu-
res gentle handling of the metered media.
Maximum pressure on suction/inlet side is 3 bar (45 psi approx.) and maximum pressure
on suction/inlet side is 0,5 bar (7,25 psi approx.) only in pumps with Norprene, Silicone
and Tygon tube).
The AMP Series has been designed for safe and uncomplicated operation, as well as
straightforward maintenance.
The AMP Series can be used for many different media. However, this pump type is often
the optimal solution for abrasive, shear-sensitive and viscous media.
Typical areas of use include processes where only a low discharge pressure is required
(max. 8 bar).
3.1.

Main modules:

1.
Drive Unit
2.
Housing
3.
Base frame
DESCRIPTION
UNIT
m3/h
Max. capacity
continuous
GPM
m3/h
Max. capacity
intermittent
GPM
l/rev
Capacity per
revolution
Gal/rev
Max. permissable
working pressure
Permissable am-
bient temperature
Permissable pro-
duct temperature
Sound level at 1m
dB (A)
AMP-10
AMP-13
0,095
0,418
0,125
0,550
0,023
0,005
bar
8
°C
-10 to +40
-10 to +40
°C
-10 to +80
-10 to +80
70
AMP-16
0,160
0,380
0,587
1,393
0,185
0,440
0,678
1,613
0,038
0,092
0,008
0,020
8
8
-10 to +40
-10 to +80
70
70
7
AMP-19
AMP-22
0,520
1
2,270
3,67
0,780
1,15
3,410
4,22
0,123
0,246
0,033
0,054
2
8
-10 to +40
-10 to +40
90
-10 to +80
70
70

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amp-10Amp-13Amp-16Amp-19Amp-22

Table of Contents