Operating instruccions Peristaltic Pumps
9.3.
Lubrication
AMP pumps only require a thin film of grease to reduce the friction between the roller and
the outer surface of the hose or tube. No other lubrication is necessary.
Lubricant quantity table
Lubricant
Silicone grease
quantity
9.3.1.
Changing oil in gearbox
The instructions manual of the gearbox are usually delivered with the IOM of the Boyser
pump.
Some models of gearbox are lubricated for life, other models of gear reducers require
regular maintenance according to the instructions manual of the gear reducer manufac-
turer.
In case of doubt, please contact the gearbox manufacturer or their authorised distributor
in your country.
9.4.
Exchanging the pump hoses
9.4.1. Dismantling
Close off all valves, in order to prevent leakage of the feed chemical.
1.
Dismantle the pipes from both discharge and suction sides.
AMP Series
Unit
AMP-10/13
-
BOYSER
gramme
50-70
ounce
1,8 – 2,5
20
AMP-16
AMP-22
BOYSER
BOYSER
50-70
100
1,8 – 2,5
3,5