8.3.2. Maximum permissible loads on the pump connection
- Pump must be bolted to floor before applying loads to connections/flanges.
F1
N
lb-f
F2
N
lb-f
F3
N
lb-f
8.3.3. Discharge side
- The discharge line is to be kept as straight and short as possible, in order to avoid
performance reduction.
- The diameter must correspond to the rated diameter of the pump hose. A larger
diameter is recommended in the event of viscous liquids.
- It is recommended to use flexible piping between the fixed pipes and the hydraulic
connections of the pump, in order to avoid the transmission of vibrations.
- Install a pressure relief valve or a pressure switch (or similar device) in the pressure
line in order to protect the pump in the event that a valve is unintentionally closed
off or the line is blocked in another way.
AMP-10
AMP-13
600
600
135
135
300
300
67
67
300
300
67
67
13
AMP-16
AMP-19
600
600
135
135
300
300
67
67
300
300
67
67
AMP-22
600
135
300
67
300
37