Boyser AMP Series Operating Instructions Manual page 5

Peristaltic pump
Table of Contents

Advertisement

- Always observe the safety data sheets for the media to be handled.
The system operator must ensure that these safety data sheets are
available and that kept up-to-date.
- The safety data sheets for the fluid being handled are always deci-
sive for initiating countermeasures and/or first aid in the event of
leakage of the fluid.
- Observe the general restrictions in relation to viscosity limits, che-
mical resistance and density.
- Always switch the pump off before exchanging the pump hose
Incorrect and improper use
Possible consequence: fatal or very serious injuries.
- The unit is not intended to convey or regulate gases or solid media
- Do not exceed the rated pressure, speed or temperature for the
pump
- Maximum pressure on suction/inlet side is 3 bar (45 psi approx.)
and maximum pressure on suction/inlet side is 0,5 bar (7,25 psi
approx.) only in pumps with Norprene, Silicone and Tygon tube).
- The unit may only be used in accordance with the technical data
and specifications provided in these operating instructions and in
the operating instructions for the individual components
- This pump is NOT supplied for use in areas of risk from explosion.
ATEX versions of BOYSER pumps are available and they are supplied
with a special ATEX version of the Instruction Manual.
- Only switch the pump on if it has been properly fastened to the
floor
- Only switch the pump on if the front cover has been attached.
- Do not carry out any maintenance operations or dismantle the
pump without first making sure that the pipes are not under pres-
sure and are empty or isolated.
- In the case of the hose becoming stuck during extraction or fitting it
is necessary to reverse the direction of the pump, re-lubricate, and
then repeat the operation.
- As the peristaltic pump is volumetric and its functioning is positive
displacement, it is necessary to prevent a possible overload of pres-
sure, due to, for example, the accidental closure of a valve. For this
reason, it is advisable to fit a safety device such as: a safety valve,
pressure limiter, etc.
Operational lifetime of the pump hoses
Possible consequence: fatal or very serious injuries.
The hose has an indeterminate life and due to the possibility of its