Boyser AMP Series Operating Instructions Manual page 15

Peristaltic pump
Table of Contents

Advertisement

The shims are fitted in the factory. The number of shims can be adapted to the actual
operating conditions according to the following tables. Slight variations in colour of polyu-
rethane rollers is normal.
8.4.1. AMP-10 Model
a) NR, NBR, EPDM, CSM, NR-A and NBR-A:
Number of shims of 0,5 mm thickness (part number 102.01.49). NOTE: for fluid temperatu-
res >60°C: reduce shim quantities by 1.
AMP-10
0,5
2,0
bar
4,0*
6,0
8,0
*Factory default setting if working pressure is not informed
N/A: Outside standard operating range of pump
b) Norprene / Silicone:
One 2,5 mm shim can be used (part number 102.01.16), alternatively five 0,5 mm shims
can be used (part number 102.01.49) for a total of 2,5 mm. NOTE: for fluid temperatures
>60°C: reduce shim quantities by 1.
AMP-10
0,5
bar
2,0
*Factory default setting if working pressure is not informed
0-19
20-39
1
1
1
1
2
1
2
2
3
2
0-19
20-39
1
1
1
1
15
rev/min
40-59
60-79
1
1
1
1
1
1
2
N/A
N/A
N/A
rev/min
40-59
60-79
1
1
1
1
80-99
1
1
1
N/A
N/A
80-99
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amp-10Amp-13Amp-16Amp-19Amp-22

Table of Contents