Operating instruccions Peristaltic Pumps
b) Norprene / Silicone:
One 5 mm shim (part number 113.00.37) plus two 0,5 mm shims (part number 113.00.33)
can be used for a total of 6 mm. NOTE: for fluid temperatures >60°C: reduce shim quan-
tities by 1.
AMP-22
0,5
bar
2,0*
*Factory default setting if working pressure is not informed
9.

MAINTENANCE

9.1.
Components weights
Total Weight
Pump Cover
Roller Sub-Assembly
Connection
Press Flange
Hose
AMP Series
0-19
20-39
1+2
1+2
1+2
1+2
AMP-10/-13
AMP-16
14 kg
23 kg
30 lbs
50 lbs
0,11 kg
3,26 kg
0,24 lbs
7,19 lbs
0,30 kg
0,60 kg
0,66 lbs
1,32 lbs
0,08 kg
0,14 kg
0,18 lbs
0,31 lbs
0,05 kg
0,07 kg
0,11 lbs
0,15 lbs
0,16 kg
0,33 kg
0,35 lbs
0,73 lbs
18
rev/min
40-59
60-79
1+2
1+2
1+2
1+2
AMP-19
23 kg
50 lbs
3,26 kg
7,19 lbs
0,60 kg
1,32 lbs
0,14 kg
0,31 lbs
0,07 kg
0,15 lbs
0,33 kg
0,73 lbs
80-99
1+2
1+2
AMP-22
49 kg
108 lbs
3,58 kg
7,89 lbs
1,06 kg
2,34 lbs
0,20 kg
0,44 lbs
0,10 kg
0,22 lbs
0,70 kg
1,54 lbs