Maintenance - Boyser FMP Series Operating Instructions Manual

Peristaltic pump
Table of Contents

Advertisement

Operating instruccions Peristaltic Pumps
8.4.6. FMP-80 Model
a) NR, NBR, EPDM and CSM:
Number of shims of 0,5 mm thickness (part number 117.00.11) in each location (i.e. mul-
tiply by 4 for total quantity of shims). NOTE: for fluid temperatures >60°C, reduce shim
quantities by 1.
FMP-80
0,5
2,0
bar
4,0*
6,0
8,0
*Factory default setting if working pressure is not informed.
9.

MAINTENANCE

9.1.
Components weights
FMP-30
82 kg
Total Weight
108 lbs
7,8 kg
Pump Cover
17 lbs
1,7 kg
Roller Sub-As-
sembly
3,8 lbs
0,4 kg
Connection
0,88 lbs
1,25 kg
Press Flange
2,8 lbs
1,7 kg
Hose
3,7 lbs
FMP Series
rev/min
0-19
20-39
0,5 mm
0,5 mm
4
4
4
4
5
5
6
5
7
6
FMP-40
FMP-50
122 kg
182 kg
268 lbs
401 lbs
11,.7 kg
11,2 kg
25 lbs
24 lbs
2,9 kg
4,1 kg
6,4 lbs
9,0 lbs
0,5 kg
1,4 kg
1,1 lbs
3,1 lbs
1,6 kg
2,0 kg
3,5 lbs
4,4 lbs
2,5 kg
3,1 kg
5,5 lbs
6,8 lbs
20
40-59
0,5 mm
3
3
4
N/A
N/A
FMP-60
FMP-70
253 kg
574 kg
557 lbs
1265 lbs
18,5 kg
31,2 kg
40 lbs
68 lbs
8,1 kg
14,7 kg
17,9 lbs
32,4 lbs
1,9 kg
3,2 kg
4,2 lbs
7,1 lbs
3,9 kg
5,5 kg
8,6 lbs
12,1 lbs
6,3 kg
11,2 kg
13,9 lbs
24,7 lbs
FMP-80
1150 kg
2535 lbs
42,8 kg
94 lbs
32 kg
70,6 lbs
5,4 kg
11,9 lbs
9,0 kg
19,8 lbs
19 kg
42 lbs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmp-30Fmp-40Fmp-50Fmp-60Fmp-70Fmp-80

Table of Contents