List of Data Points (HMI-SG controller)
Parameter
Notation
Reading
code
level
code
level
139
U
140
G
Temperature mode setting "Higher"
(Ext. control 2 contacts)
Fans - Modbus
141
A
Inlet fan output St1 setting
142
A
Inlet fan output St1 setting (násobitel 10)
143
A
Inlet fan output St2 setting
144
A
Inlet fan output St2 setting (násobitel 10)
145
A
Inlet fan output St3 setting
146
A
Inlet fan output St3 setting (násobitel 10)
147
A
Inlet fan output St4 setting
148
A
Inlet fan output St4 setting (násobitel 10)
149
A
Inlet fan output St5 setting
150
A
Inlet fan output St5 setting (násobitel 10)
151
A
Outlet fan output St1 setting
152
A
Outlet fan output St1 setting (násobitel 10)
153
A
Outlet fan output St2 setting
154
A
Outlet fan output St2 setting (násobitel 10)
155
A
Outlet fan output St3 setting
156
A
Outlet fan output St3 setting (násobitel 10)
157
A
Outlet fan output St4 setting
158
A
Outlet fan output St4 setting (násobitel 10)
159
A
Outlet fan output St5 setting
160
A
Outlet fan output St5 setting (násobitel 10)
161
A
162
U
3rd fan output St1 setting
163
A
164
U
3rd fan output St2 setting
165
A
166
U
3rd fan output St3 setting
167
A
168
U
3rd fan output St4 setting
169
A
170
U
3rd fan output St5 setting
171
A
172
U
Fan run-out after unit stop shut-down
570
A
Allow fan run-on based on the plate heat exchanger
571
A
Unit run-on based on the plate heat exchanger - blocked by the outdoor temperature Min
572
A
Unit run-on based on the plate heat exchanger - blocked by the outdoor temperature Max
573
A
Unit run-on based on the plate heat exchanger - time
Inlet backup – single-speed motors
173
A
174
U
Failure flow evaluation time-out after main fan start-up
175
A
176
U
Failure flow evaluation time-out af-
ter backup fan start-up
181
U
Information – backup activation
Outlet backup - single-speed motors
177
A
178
U
Failure flow evaluation time-out after main fan start-up
179
A
180
U
Failure flow evaluation time-out af-
ter backup fan start-up
182
U
Information - backup activation
TRN correction
183
A
183
A
Common for all operating stages St
32
Menu HMI-SG
Meaning
4
Stage 3
5
Stage 4
6
Stage 5
0
Comfort
1
Economy
0
No
1
Yes
0
non-activated
1
activated
0
non-activated
1
activated
0
- 4 stages
1
- 3 stages
2
- 2 stages
3
- 1 stage
4
0
Factory Settings
Value
Min
Max
0
Regulation
limits
0,1
% (m3/h, Pa)
% (m3/h, Pa)
25
% (m3/h, Pa)
% (m3/h, Pa)
50
% (m3/h, Pa)
% (m3/h, Pa)
75
% (m3/h, Pa)
% (m3/h, Pa)
100
% (m3/h, Pa)
% (m3/h, Pa)
0,1
% (m3/h, Pa)
% (m3/h, Pa)
25
% (m3/h, Pa)
% (m3/h, Pa)
50
% (m3/h, Pa)
% (m3/h, Pa)
75
% (m3/h, Pa)
% (m3/h, Pa)
100
% (m3/h, Pa)
% (m3/h, Pa)
0,1
0,1
100
%
25
0,1
100
%
50
0,1
100
%
75
0,1
100
%
100
0,1
100
%
180
0
9999
s
1
-15
-64
64
°C
5
-64
64
°C
5
1
60
Min
180
0
9999
s
180
0
9999
s
180
0
9999
s
180
0
9999
s
0