Jumper Plug Programming - CrimeStopper CS-2004 WDC Installation And Operating Instructions Manual

Remote control alarm system with coolglow & securwatch
Table of Contents

Advertisement

The jumper plugs are located on the topside of the control module behind a small access door. To change the
programmable options on this system, jumper pins must be removed or shorted. See the diagram and chart for alarm
configuration options.
REMOVE
DOOR
TOP OF MODULE
* This unit must
be powered down
and powered back
up after making
any Jumper Pin
changes from P4
through P9 to
allow the module
to read the new
settings.

JUMPER PLUG PROGRAMMING

P1 P2 P3 P4 P5 P6 P7 P8
PIN #
SHORTED
P1
Passive Arming
P2
Passive Door Locks
P3
Door-open warning 5
Sec. after armed
P4*
Autolock with Ignition
P5*
1 Sec. Lock/Unlock
Pulse
P6*
Single Unlock Pulse
P7*
Normally Closed
Starter Disable
P8
Not Used
P9*
Button 2 = AUX. 1
OPEN
(REMOVED)
SHORTED
(ATTACHED)
OPEN
NO Passive Arming
NO Passive Locks
No Door-open
warning after armed
NO Autolock
3 Sec. Lock/Unlock
Pulse
Double Unlock Pulse
Normally Open (High-
Security Starter
Disable
Not Used
Button 2 = Remote
Carjack Activation
JUMPER
PLUG
JUMPER
PINS
SIDE VIEW