CONGRATULATIONS on your choice of a Gargoyle™ Remote Alarm System by Crimestopper Security
Products Inc. This system features DYNAMIC CODE anti code-grabbing technology. The remote control
code changes with every use of the transmitter making it impossible to scan or record the codes for use later
on. This booklet contains the information necessary for installing, using, and maintaining your alarm system.
If any questions arise, contact your installation dealer or Crimestopper Security Products Inc. at the Tech
Support number below.
*IMPORTANT INFORMATION: Primary and Optional Features
-PRIMARY: These are features that must be connected in order for the system to operate properly i.e. Siren,
L.E.D., Power, Ground, Doorpin, etc.
-OPTIONAL: These are features to be connected only if desired or agreed upon by the installing dealer (i.e.
Door Locks, Flashing Lights, Starter Kill, Hood, Trunk, and Auxiliary Remote Outputs etc.)
TECH SUPPORT
Mon-Fri 8:00 AM-4:30 PM Pacific Time
(800) 998-6880
INTRODUCTION
This device complies with FCC Rules part 15. Operation is subject to the following
two conditions: 1) This device may not cause interference, and (2) this device
must accept any interference that may be received, including interference that may
cause undesired operation. The manufacturer is not responsible for any radio or
TV interference caused by unauthorized modification to this equipment. Such
modification could void the user's authority to operate the equipment.

Advertisement

Table of Contents
loading

Summary of Contents for CrimeStopper CS-2002

  • Page 1 This booklet contains the information necessary for installing, using, and maintaining your alarm system. If any questions arise, contact your installation dealer or Crimestopper Security Products Inc. at the Tech Support number below.
  • Page 2: Installation Cautions & Warnings

    INSTALLATION CAUTIONS & WARNINGS BEFORE BEGINNING, check all vehicle manufacturer cautions and warnings regarding electrical service (AIR BAGS, ABS BRAKES, AND BATTERY). TO PREVENT A POSSIBLE DEAD BATTERY remove vehicle dome light fuse while working on the vehicle. MAKE CERTAIN TO REINSTALL FUSE PRIOR TO TESTING FOR DOOR TRIGGERS. DO NOT EXCEED MAXIMUM OUTPUT RATINGS! - SERIOUS DAMAGE MAY OCCUR.
  • Page 3: Component Mounting

    COMPONENT MOUNTING SIREN MOUNTING: Mount the siren under the hood to fender-well or other body surface with the open end facing downward. Run the red siren wire through the firewall using a rubber grommet. Ground the black wire to the body metal near the siren.
  • Page 4 BLUE WIRE: (-) HOOD/TRUNK TRIGGER Input trigger for a grounding hood or trunk pin switch. Connect to existing hood and trunk pin switches that read ground when open. If no existing switches are available, install new pin switches if desired. Note: DO NOT mount new pin switches in water pathways.
  • Page 5: Power Door Lock Wiring

    3 PIN DOOR LOCK PLUG (Optional): GREEN: (-) Negative pulse for LOCK RED: +12V Coil Power for external relays TERM 86. BLUE: (-) Negative pulse for UNLOCK DETERMINING DOOR LOCK TYPE: We recommend determining the type of locking system the vehicle has before connecting any wires.
  • Page 6 POWER DOOR LOCK WIRING REVERSE POLARITY DOOR LOCK WIRING GREEN BLUE MASTER SWITCH SEPARATE DRIVER’S DOOR UNLOCK WIRING NEGATIVE TRIGGER DOOR LOCKS BLUE/WHITE GREEN BLUE DRIVER'S DOOR MOTOR UNLOCK WIRE AFTERMARKET MOTOR/DOOR LOCK WIRING GREEN FUSED +12V BLUE UNLOCK FACTORY LOCK RELAYS +12V FUSED...
  • Page 7 SEPARATE DRIVER’S DOOR UNLOCK WIRING WIRING FOR POSITIVE TRIGGER DOOR LOCKS BLUE/WHITE GREEN BLUE DRIVER'S DOOR +12V FUSED UNLOCK WIRE WIRING FOR REVERSE POLARITY DOOR LOCKS BLUE/WHITE GREEN BLUE DRIVER'S DOOR 30 87A UNLOCK WIRE FACTORY LOCK RELAYS FUSED +12V...
  • Page 8: Transmitter Programming

    1. Turn Ignition ON and OFF 3 times quickly, leaving it ON the 3 chirps. 2. Push and release the Program/Override Button 5 times and the Status LED will come on solid. 3. Press #1 (LOCK) on new transmitter two times. LED goes out, siren chirps one time, and LED will flicker for confirmation.
  • Page 9: Passive Arming

    CS-2002DC PROGRAMMABLE OPTIONS 1. Turn the Ignition ON and press the Override/Program button 5 times. You should hear 6 confirmation chirps. 2. Within the next few seconds, press the Override/Program button [again] the number of times that corresponds to the feature list below. The siren will chirp for each button press. DO NOT LOSE COUNT!! 3.
  • Page 10 OPTION PROGRAMMING 2. SOFT CHIRP ARM / DISARM WITH BUTTON #3 (SHORT PRESS) With this feature, the system can be programmed to Arm and Disarm with a very soft siren chirp using a short press on button #3 on the remote. The Factory Default setting is ON. 3.
  • Page 11: Operation

    OPTION PROGRAMMING 12. ACTIVE or PASSIVE CARJACK PROTECTION This feature controls the alarm system’s Carjack Mode for ACTIVE OR PASSIVE protection. Option number 9 Must be enabled to allow Carjack functions to operate. See Operation section for Carjack Features. Factory default is Active. 13.
  • Page 12 OPERATION DISARMING To disarm the alarm and unlock the doors, press the #2 (Unlock Symbol) button on the transmitter. You will hear 2 siren chirps and the lights will flash twice. The dome light turns on and the dash LED stops flashing. TRUNK/HATCH POP (REMOTE AUX.
  • Page 13 OPERATION SOFT CHIRP ARM/DISARM This system can be armed and disarmed with very faint/soft chirps as needed. Press and quickly release Button #3 (Trunk pop) to Arm and Disarm system with soft chirps. Note: If Button #3 is pressed too long, then the Aux. 1 output will activate.
  • Page 14: Carjack Protection

    OPERATION AUX. OUTPUT (REMOTE AUX. OUTPUT 2) To activate the Second auxiliary output press Button #1 (Lock) and hold for more than (1) second. This output can be used to control other optional add-on accessories such as Remote Engine Start Modules, Window Roll up/down modules, etc.
  • Page 15 (-) NEG. DOOR PIN SWITCH (+) POSITIVE DOOR PIN SWITCH GREEN (-) DOOR TRIGGER VIOLET (+) DOOR TRIGGER IGN. BLACK CHASSIS GROUND FUSE YELLOW (+) SWITCHED IGN "ON" GRAY OPT. (-) REMOTE OUTPUT 1 RELAY BLUE (-) HOOD/TRUNK TRIGGER (-) NEG. PIN SWITCH (-) DOME LIGHT OUTPUT DOME LIGHT...
  • Page 16 CS2002DC REVA 2.1.00 Crimestopper Security Products 1770 S. Tapo Street Simi Valley, CA 93063...

This manual is also suitable for:

Cs-2002dc

Table of Contents