Shielding (Functional Earth)
Note that protection from influence by
electromagnetic fields is not provided if
the shield is not earthed.
Connect the shield at each cable end to system
X
ground over a large area.
Avoid pointed contact and twisting of the shield.
X
6.4
Protective earthing
To avoid voltages applied to the housing
in the event of a fault, the motor hou-
sing must be grounded. Cable shields
must be low-inductive earthed on both
sides.
For electrically isolated assembly, the motor housing
X
must be connected to the machine earth via a sepa-
rate earth connection.
Connect and earth the ground of the power and logic
X
supply at a defined location in the system.
Page/Seite 48 / 102