HoMedics BPW-930BT Manual page 25

Automatic wrist blood pressure monitor
Table of Contents

Advertisement

Guidance and manufacturer's declaration - electromagnetic Immunity
The device
is intended
for
use in
the electromagnetic
environments listed
below,
and should only
be used
in such environments:
Immunity test
Conducted RF
IEC 61()()()-4-6
Radiated RF
IEC 61000-4-3
Proximity fields
from RF wireless
communications
equipment
I
EC
61 000-4-3
IEC 60601 test level
3Vrms
At0.15-BOMHz
6Vrms
At ISM & Radio
Amateur Freq
1
o
V/m at 80-2700
MHz
AM
Modulation
And 9-28V/m at
385-6000MHz,Pulse
Mode
and
other
Modulation. The
system shall be
tested
as
specified in
IEC60601-1-2 Table
9 for proximity fields
from RF wireless
communications
equipment using the
test methods specified
in IEC 61000-4-3
Compliance level
Not
Applicable
1
o
V/m at 80-2700
MHz
AM
Modulation
And 9-28V/m at
385-6000MHz,Pulse
Mode
and other
Modulation.
The
system shall be
tested
as
specified in
IEC60601-1-2 Table
9 for proximity fields
from RF wireless
communications
equipment using
the test methods
specified in !EC
6100043
NOTE
1: At 80 MHz and 800 MHz, the higher frequency range applies.
Electromagnetic environment -
guidance
Portable and mobile RF communications
equipment should
be
used no closer to any
part of the device, Including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency
of the transmitter.
Recommended separation distance
Considering to reduce the minimum
separation distance, based on RISK
MANAGEMENT,
and
using higher
IMMUNITY
TEST
LEVELS that are appropriate for the
reduced
minimum separation distance.
Minimum
separation distances for higher
IMMUNITY
TEST LEVELS shall be calculated
using the following equation:
E
=
6/dff
where
P
is the maximum power in
w,
d ,s the
minimum separation
distance
in m, and E is
the
IMMUNITY
TEST
LEVELS in V/m.
Field strengths
from
fixed
AF
transmitters,
as
determined by
an electromagnetic site survey,
8
should be less than the compliance level in
each frequency
range.
b
Interference may occur in the vicinity of
equipment marked with the following
symbol:
(t'i'))
NOTE
2:
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
a: Field strengths from fixed trans-milters, such as base stations for radio (cellular/cordless) tele-phones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast can-not be predicted
theoretically with
accuracy.
To assess the electro-magnetic environment due to fixed RF transmitters, an electromagnet-ic site survey should
be considered.
If
the measured field strength in the location In which the device is
used exceeds the ap-plicable RF
compliance level above, the device should be ob-served to verify normal operation. If
abnormal performance
is observed,
additional measures may be necessary, such as reorienting or relocating
the
device.
b: Over the frequency range 150 kHz to 80
MHz,
field strengths should be less than 3 V/m.