Wiring Schematic; Wiring Notes - Assa Abloy ES8100 Installation Manual And User's Manual

V-lock
Table of Contents

Advertisement

POWER
CIRCUITRY
INDICATION
AND
LED
MOTOR
CONTROL
DOOR POSITION MONITOR
(50mA @ 30VDC)
Contact is closed when
strike plate is present.
LOCK STATUS MONITOR
(50mA @ 30VDC)
Contact is closed when
bolt is fully extended and
locked.
3 wire operation is recommended when using the ES8100 : V-lock.
2 wire operation is possible in PtL setting only. Lock will operate slower when operated in 2 wire mode.
Ensure ground reference is common for both power (red) and control (blue) cables.
3 Wire control
-
+
Door controller
Power
relay
supply
Cable
Distance
cross section
5m
0.33mm
10m
0.65mm
15m
1.04mm
3 Wire control
-
+
Power
supply
Ensure ground references are common
Cable gauge requirements
American
wire gauge
2
AWG22
2
AWG19
2
AWG17
Supply power
0VDC (Black)
Supply power
12 - 24VDC (Red)
Lock control
12 - 24VDC (Blue)
Door Position Monitor
(NC) (Green)
Door Position Monitor
(C) (Yellow)
Lock Status Monitor
(NO) (Orange)
Lock Status Monitor
(NC) (White)
Lock Status Monitor
(C) (Purple)
-
+
Door controller
Power
relay
supply
Cable
Distance
cross section
20m
1.31mm
30m
1.63mm
50m
2.05mm

WIRING SCHEMATIC

Schematic shows lock in locked
state with strike in position.
Join for 2 wire operation.
2 wire operation is only
possible in PtL setting.

WIRING NOTES

2 Wire control (PtL only)
-
+
Door controller
Power
relay
supply
American
wire gauge
2
AWG16
2
AWG14
2
AWG12