Cos phi
Max. permitted mains impedance Z
Recommended residual current circuit breaker
Welding current range (I
Welding current range (I
Welding current for MMA welding 10 min / 40 °C
(104 °F)
Welding current for TIG welding 10 min / 40°C
(104°F)
Output voltage range according to standard char-
acteristic (U
Output voltage range according to standard char-
acteristic (U
Open circuit voltage (U
Protection class
Type of cooling
Overvoltage category
Pollution degree according to IEC60664
EMC emission class
Safety symbols
Max. shielding gas pressure
Dimensions (length x width x height)
Weight
Idle state power consumption
at 230 V
Energy efficiency of the welding system at
150 A / 26 V
1)

Ignis 180 TIG

Mains voltage (U
Max. effective primary current (I
Max. primary current (I
Max. apparent power (S
Mains fuse
) rod electrode
2
) TIG
2
) rod electrode
2
) TIG
2
peak)
0
Interface to a 230/400 V and 50 Hz public grid
)
1
)
1max
)
1max
1)
at PCC
max
35 %
150 A
35 %
150 A
)
1eff
0.99
32 mOhm
Type B
10-150 A
10-150 A
60 %
100 %
110 A
90 A
60 %
100 %
110 A
90 A
20.4-26 V
10.4-16 V
96 V
IP 23
AF
III
3
A
S, CE
5 bar
72.52 psi
365 x 130 x 285 mm
14.4 x 5.1 x 11.2 in.
6.6 kg
14.6 lb.
15 W
87%
1 x 230 V
16 A
25 A
5.75 kVA
16 A slow-blow
55