Table Of Contents; Technical Data - Pepperl+Fuchs DoorScan Original Operating Instructions

Active infrared sensor for person detection on automatic doors with a width of up to 1600 mm
Table of Contents

Advertisement

DoorScan

Technical Data

Table of Contents

Technical Data ......................................................................................................................................4
Accessories ..........................................................................................................................................5
Device Versions ....................................................................................................................................5
Display and Control Elements ...............................................................................................................6
Application Notes ..................................................................................................................................7
Mounting ...............................................................................................................................................9
Commissioning (Teach-in and Blanking) .............................................................................................14
Adjusting the sensor ...........................................................................................................................15
Close the Sensor ................................................................................................................................18
Fault Indications ..................................................................................................................................19
Declaration of Conformity ...................................................................................................................21
Technical Data
General
Characteristic
Functional principle
Mounting height
Light source
Operating voltage
Switching mode
Switching voltage/current
Current consumption
Response time
Ambient temperature
Relative humidity
Degree of protection
Connection
Material
Default Settings
Function
DIP switches
Adjustment wheel
4
Description
Active infrared scanner with background evaluation
1500 mm to 3500 mm for upright CA reference object
IRED, 850 nm
24 VDC +/-20 %
Light ON
npn/30 VDC/max. 100 mA, pnp/max. 100 mA
Max. 200 mA
52 ms/200 ms in boost operating mode
-30 °C ... 60 °C
25 % ... 95 %, noncondensing
IP54 in accordance with EN 60529
Plug-in terminal with 6-wire connection cable
Sensing strip: Aluminum
End cap: PA
Sensor cover: PC
Setting
Row 1:
Switches 1-4 down (OFF)
Row 2:
Switch 1 down (OFF)
Switch 2 down (OFF)
Switch 3 up (ON)
Switch 4 up (ON)
Position 0