Commissioning (Teach-in and Blanking)

Commissioning (Teach-in and Blanking)
During Teach-in, the sensor first learns the floor surface and then, during a subsequent door opening
and closing procedure, the detection area. If the sensor detects walls in the detection area during the
door opening and closing procedure, these are also taught into the sensor and suppressed (blanking),
in order to enable full door opening during subsequent operation. Following successful blanking, the
sensor function is guaranteed up to a full opening of the door. If the wall structure contains elements
that are unsuitable for blanking, the sensor permits blanking until these elements are detected. Ele-
ments that are unsuitable for blanking include heating units, protrusions, or pillars.
For Teach-in, remove all objects from the door area that are not part of the usual environ-
ment, and step out of the detection area of the sensor.
If no wall suppression is required, set the DIP switch 4 in row 2 to the OFF position. Other-
wise, leave it in the ON position.
14
20 sec
i
nformation
Teach-in process
1. Teach LED (YELLOW) on the interface is
illuminated or flickering: Sensor is ready for
Teach-in.
2. Press the Teach button (RED):
1x if LED is illuminated /
2x if LED is flickering
Teach LED is flashing slowly:
Surface/floor is taught-in.
Teach LED is flashing quickly:
Teach-in of the surface/floor is complete.
Teach-in of the environment begins.
In the event of a flashing red status
LED, see "Fault Indications" on the
following page.
3. Start a complete door opening and closing
procedure at standard speed inside of 20 sec-
onds(with buttons or remote control).During
the door opening and closing procedure, the
environment and any wall are taught in.
4. Teach LED is off.
If there is no wall in the door area, the Blank
LED is off.
If there is a wall in the door area:
The Blank LED is illuminated: The wall was
taught in fully
The Blank LED is off: The wall was not
taught in fully. In this case, if the door does
not open fully, set the wall suppression on
the drive.