Fault Indications - Pepperl+Fuchs DoorScan Original Operating Instructions

Active infrared sensor for person detection on automatic doors with a width of up to 1600 mm
Table of Contents

Advertisement

DoorScan

Fault Indications

Fault Indications
Fault after floor Teach-in
Yellow Teach LED on the
Red status LED on the
interface is flashing
interface is off
Red status LED on the
interface is flashing twice
Red status LED on the
interface is flashing four
times
Fault after wall Teach-in
Yellow Teach LED on the
Red status LED on the
interface is flashing
interface is on
Red status LED on the
interface is flashing
three times
Yellow Teach LED on
Red status LED on the
the interface is off
interface is off
Red status LED on the
interface is flashing
rapidly
Receiver LED
Receiver is not
is off
functioning
Receiver LED
System error
is flashing once
in receiver
Receiver LED is
Base width is
flashing twice
too big
Receiver LED is
Object in the
flashing three
detection area
times
Base width is
much too big
Emitter and receiver
modules are not
aligned correctly
with one another
Emitter module is
not working
Metal foot grid in the
detection area
Receiver module is
Receiver LED
defective
is flashing four
times
Interface module
is defective
Receiver LED is
Memory access fault at the
flashing once
receiver module
Receiver LED is
Assignment of the interface to the
flashing once
door hinge side/hinge opposite
side is set up incorrectly
Sensor on the hinge opposite
side detects an object
Floor level on the hinge opposite
side is lower than on the door
hinge side (level, threshold)
Memory access interface (green
Receiver LED is on
DIP LEDs are flashing)
Receiver LED is
flashing rapidly
Signal strength is too
Door or sensor profile warped
low
Very dark or reflective surface
Check the contact with the ribbon cable on all modules.
Replace the receiver module
Switch the operating voltage off and then on again
Replace the receiver module
Reduce the distance between the modules
Remove the object or increase the distance from the door
jamb on the side wall
Reduce the distance between the modules
Turn angle adjustment to the same position, check that the
emitter and receiver modules are correctly engaged in the profile
and that they are not being subjected to pressure from cables
etc. Check the emitter and receiver modules for damage (twisted
plastic pins on the adjustment wheel) and replace if necessary
Check the contact with the ribbon cable on all modules.
Replace the emitter module
Activate metal foot grid mode
Replace the receiver module
Replace the interface
Repeat Teach-in process
Change the settings of DIP switch 2
Remove the object
Activate metal foot grid mode and align
the floor level during the Teach-in
process if necessary
Repeat Teach-in process
Inclination angle on the receiver module
a) Decrease in increments until the
sensor switches to detection mode;
note the setting
b) Increase in increments until the
sensor switches to detection mode;
note the setting
c) Set to the mean of both values
Activate boost operating mode. Note:
This will increase the response time of
the sensor.
19