DoorScan
Adjusting the sensor
Adjusting the sensor
Attach the end caps but do not tighten them yet.
Select Output Configuration
0
i
nformation
DoorScan Detection Area
The sensor uses the active-infrared principle and forms a continuous de-
tection field that is almost rectangular on each side of the door. If a person
or object interrupts one or more of the light beams, the sensor's switching
function is triggered.
The detection field is composed of ten beams. It adapts automatically to
the door width, and the sensor disables any unnecessary beams. The
slightly inclined position of the outer beams makes the leading edges and
hinge edges of the doors more secure.
The sensor system has a modular construction and can be adapted to a
wide range of door widths and ambient conditions.
When used with horizontal handles, the detection area must be located in
front of the handle.
1 8
You can configure the outputs to NPN or
PNP if you connect the plug-in jumper
on the interface module as shown in the
schematic diagram on the housing.
Set the Inclination Angle
Recommended settings in accordance
with DIN 18650/EN 16005:
•
Position 8 for 1900 mm ... 2200 mm
mounting height
•
Position 6 for 2500 mm mounting
height
•
Position 5 for 3000 mm mounting
height
•
Position 4 for 3500 mm mounting
height
•
Position 0*
* Factory default setting
15