Operating Issues

In the unlikely event that your system shuts itself down for any reason, you must identify and correct
the problem that has caused the safety system to operate before allowing anyone to use the iCool.
Never restart without identifying and correcting any fault.
Compact Not Cooling or
Heating
Your iCool has several safety systems including one that
prevents the gas pressure reaching a dangerous high level.
This can only happen if the machine is extremely overheated.
If the machine has been operated in very hot conditions, in
a confined space or if the airflow has been blocked or partly
blocked for a certain amount of time, or if it's placed too close
to a wall, towel, source of heat or other object, it may cause the
extreme temperature/high pressure safety system to operate
causing some or all of the refrigeration gas to be lost.
Damage resulting by any of those reasons will not be
covered under warranty.
If your chiller is running normally but hasn't changed
temperatures after more than an hour, please first make sure
that the Target Temp is lower than the actual pool temp.
If it seems to be running correctly but is not cooling (or
heating) at all, or not as well as normal, it may be due to a loss
of refrigeration gas and will need to be re-charged.
DO NOT OPERATE IT UNTIL THIS IS CORRECTED OR SERIOUS
DAMAGE CAN OCCUR.
Re-charging the refrigerant can be done by your local
refrigeration repair person. The type of refrigerant gas and the
amount needed is marked on a certificate fixed to the heat
exchanger tank inside the machine.
Most Compact machines require 350 grams of R290.
32
"System Too Hot" Warning
Your machine can move large amounts of heat per hour.
Naturally this heat needs to be removed into the air
surrounding the system. The powerful fan can normally handle
this with ease, however if the air flow around the iCool is
restricted so that the heat can not escape, or the outside air
temperature is more than 45ºC, eventually the system will
reach the limits of its safe operating range. If the temperature
inside the cabinet exceeds 60ºC the safety system will shut it
down, sound an alarm and display the warning screen.
Please make sure that the fan is actually and the condenser
fins on the back of the machine are not covered or restricted
and that the area has a good flow of fresh air.
On very hot days when the air temperature is more than 45ºC
it may not be possible to run the system at full power due to
the excessive heat build up.
Cooling a pool that has previously been heated can also cause
a heat overload warning and shut down. This will only occur
if the pool is above 30-35ºC when you start to chill it. It is
good practice to allow the heat to reduce naturally to below
30ºC before starting the cooling cycle. This also saves a lot of
electricity.
Software Not Loading
If the software doesn't load for any reason, we recommend
turning the unit OFF and ON first to see if that solves the issue.
If the issue persists, please contact iCool Support.