Page 5
What’s new in Series 2 The MiPods are in a class of their own being the most technically advanced and the most powerful chilling systems of any comparable product available on the market. They give you the fastest chilling performance available anywhere. Manufactured from the highest quality materials and components for long service life, ice bath sessions are quick to set up and easy to use.
Page 6
Identify your MiPod This manual is intended to help you get started using the MiPod Range of all-in-one products. To know your device’s features, specifications and operation instructions, you will first need to identify your product. Below are some guidelines to help you determine your model, your series and your voltage. Identify your model Chrome Strip Your device’s model name is printed on your order/invoice and...
Page 7
Left Side View Back View Compact MiPod Series with Internal Heat Pump Ser i e s 4 support@icoolsport.com Model: MiPod Chill Made i n Aust r a l i a Rated Voltage: Rated Frequency: 220V AC Single phase 50/60Hz Components compl y wi t h...
Specifications * Data calculated with 500L of water and cooling from 25ºC down to 5ºC. Please note, the time taken each time depends on many variables: the amount of water, the surrounding room temperature, the ventilation of your machine, the initial water temperature. Leave the unit Always On so you can enjoy an ice bath anytime you want.
Page 9
** MiPod Remote can be connected to any unit from our Portable chillers range. Must be ordered at the same time as custom water connections are pre-fitted in the factory. Installation recommended to be completed by a certified plumber.
Minimum 300mm Prepare for set up Min. 300mm Min. 300mm To make setup as smooth as possible, please follow Minimum 300mm carefully the instructions outlined below. Do not start your MiPod until you have read this entire owner’s WALL or OBSTRUCTION manual.
Page 12
MiPod Chill/Hot/Dual Temp For models with an internal built-in chiller, the first step is to connect the MiPod to the power and to the screen. You must absolutely make sure that you do not connect your MiPod machine to the wrong voltage or this will cause serious damage not covered under warranty.
Page 13
1. Connect MAIN POWER SCREEN NOT CONNECTING Plug the power cable to the Main Power socket If the screen does not light up when turning ON the to a 3-pin earthed wall socket rated at least 13 Amps at 220 switch of the MiPod, please make sure that: volts (and 26 Amps at 110 volts if your machine is 110V).
Page 14
MiPod Remote For models with an external refrigeration unit, installation is recommended to be completed by a certified plumber. PVC plumbing pipes (not supplied) will need to be connected between the MiPod and the external chiller. The rest of the operation must be followed as per the chillers Owner’s Manual purchased (different to this manual).
Page 15
Davey Cartridge Filters MiPod Ice (optional) For models with no chiller at all, there is no installation required. Just fill your pool with water and add ice. That’s it! An external filter can be purchased however it must be ordered at the same time and cannot be retrofitted on existing MiPods.
Page 16
Fill with water Fill pool with water and allow enough space to handle water displacement and prevent overflow when users enter the pool. This is particularly important if you intend to have 2 or 3 people at the same time. Make sure the bath is filled with enough water as recommended on the right.
A few seconds later, operating page automatically, however in some circumstances the iCoolsport logo will appear. this page may appear because it has not yet recognized your MiPod. If this happens, after a short time a small blue square This will continue until your machine has loaded its operating appears at the top left of the screen (as shown below).
Page 21
That’s it! Your machine will now do all the rest and there is nothing else for you to do. It has been designed to always be on and ready to use. Your MiPod has been manufactured using quality components from the world’s leading manufacturers and is therefore CURRENT POOL PROGRESS BAR capable of continuous 24/7 operation.
Basic Settings The new user interface looks and works exactly like a smartphone. You can change different basic settings like the temperature unit, the volume and more by clicking on the menu button. HOME Light/Dark mode The Main Operating Screen (or Home Screen) allows you to see the current temperature of your pool, machine and the You can change the display mode pre-selected temperature.
Page 23
LOCK TIMER You can also lock your screen by entering a 4-digit passcode. This will limit the access to the settings of the chiller. Your MiPod screen has a built in SESSION TIMER. Touch the blue MENU button to reveal all available options on your To set a passcode, go to MENU >...
Particular care must be taken on all surfaces on or near this function. Make sure all operators and users know baths. iCoolsport will not accept any liability for injury where the ORANGE button is to remove all power. This or death from slips or deaths in and around the ice button is located on the Main Power Switch.
Page 26
BUILT-IN SAFETY SYSTEMS ADVICE ABOUT POOL CHEMICALS Your iCool has many essential safety features to The pool is provided with a high quality water protect against such things as: pump especially designed for the purpose. The pumps we provide are resistant to chlorine and salt water at normal concentrations, but the use of A loss of water flow chemicals should be kept within the range normally...
Maintenance It is recommended to clean your MiPod often to avoid rust and dust building up and reducing performance or causing other problems. For best results, use a microfibre cloth to clean your pool. Operation Operation in Very Cold Weather The ideal operation temperature is indoors between 10 &...
Page 30
Water Flow Issues To protect the pump and the titanium heat exchanger tanks, the system will not allow operation unless the water flows correctly. If water does not flow smoothly or if there is air trapped in the system for more than 2 minutes, the safety system will first attempt to fix it by causing the pump to surge a few times, but if that fails it will direct a shut down for safety.
Page 31
Unable to Fix Water Flow Issue Heat Exchange Tanks Frozen Solid An explanation will appear in the middle of the screen to notify you the machine has stopped. if you set the temperature below about 7ºC or 45ºF, it is occasionally possible in certain climatic conditions for the heat exchange tanks to freeze solid.
Operating Issues In the unlikely event that your system shuts itself down for any reason, you must identify and correct the problem that has caused the safety system to operate before allowing anyone to use the iCool. Never restart without identifying and correcting any fault. MiPod Not Cooling or Heating “System Too Hot”...
Page 33
Screen Freeze Condensation This is a very rare issue. If the screen freezes while the iCool Please note that your unit is a very powerful chiller and is running normally, the main computer will usually still carry condensation will occur inside of it. Water may be visible on running the system and monitoring the safety features inside the MiPod in the built-in area, this is completely but you will not be able to change anything and the displayed...
Page 34
Technical Support Before contacting iCoolsport, please make sure you have read through the entire manual. Most issues can usually be fixed via email, alternatively, we can offer a factory repair or we can assist in arranging for a local repair agent to do repair works. We will always do our best to get back to you on the same day, however please allow up to 72 hours due to time zone differences.
Page 35
Support Request Form iCool-certified Repairs Customer Name/Last Name: To get iCool-certified repairs from our iCool Head Office in QLD, Australia, simply send your product to us and we’ll assess the issue for you. Phone Number: Cost All freight costs will be at your charge (except return freight for Email address: approved warranty claims).