Maintenance

We recommended cleaning your Compact machine often to avoid dust and debris building up and
reducing performance or causing other problems. For best results, use a microfibre cloths and mild
cleaners to clean your unit.

Operation

The ideal operation temperature is indoors between 10 &
25ºC. You must protect the machine from dirty areas, freezing
temperatures or direct sun. Our machines are built from
premium materials and are well protected, but must not be
used for long periods in highly corrossive seaside areas or
outside in extreme weather conditions.
Sanitisation
The use of chlorine, salt and mild chemical disinfectants,
ozone and UV is acceptable but do not use bromide as it is
excessively corrosive.
Water Filter
If using a water filter, we recommend cleaning it every week
and replacing the internal cartridge every 6 months.
Storage
If not in use, your chiller must be emptied and kept ideally
between 15 and 25ºC, and protected from extreme weather
conditions. Never leave water inside the heat excanger tank
if the weather will be below zero. Expanding ice can cause
serious damage.
Transport
Always move the machine by holding the handles. The
machine CAN ONLY OPERATE IN AN UPRIGHT POSITION.
Never lay on on its back or front sides.
COOL
Compact
Operation in Very Cold Weather
If your Compact was specifically ordered for weather
conditions below freezing, you may have an anti-freeze
system installed. This function is automatic and will cause the
machine to stop occasionally to melt any build up of ice.
If extreme cold conditions are expected, empty the water from
the unit. If not being used, do not allow the internal tank to
freeze solid. Either empty the water or add salt or anti-freeze
to lower the temperature at which the water freezes. If not in
use, drain the unit and store at ambient temperature.
Operation in Very Hot Weather
iCool Compact machines are very powerful and capable of
removing up to 7,500 watts of heat from the water (25,000
BTUs) depending on the model.
To remove waste heat from the powerful heat pump a
powerful high flow cooling fan is installed. The fan is designed
to move up to 3000 cubic feet of air per minute. Air flow must
never be blocked by any object. It must be well clear of walls.
If the temperature inside the Compact exceeds 60ºC the over
heat safety circuit will operate and shut it down. The screen
will give advice as to when it can be safely restarted. This may
occur in very hot weather, or if the airflow is blocked by being
placed too close to a wall or if an object such as a bath towel is
blocking the air flow.
Never place the back of your iCool machine closer than
300mm (12 inches) from a wall or other obstruction that
would restrict the flow of cooling air. Never operate your
MINIMUM WATER LEVEL
chiller in a confined space such as a cupboard or very small
room, make sure there is enough airflow at all times.
POOL
Damage resulting from failure to follow these guidelines will
not be covered under warranty.