setting the desired value. Push and hold
to exit this menu at any time, into a manual operation mode.
Start up wizard:
When first time connecting the thermostat to power, or
by accessing installer menu, following parameters can be
adjusted:
No.
Parameter settings
P01
Set time (Set Hour)
P02
Set time (Set Minute)
P03
P04
Temperature control mode
P05
Max. floor temperature
P06
Window open function
P07
Frost protection funciton
P08
Set frost protection temp.
P09 Set minimum floor temperature
P10
Minimum floor temperature
P11
Installation Guide
Set weekday
Startup wizard
button, for 2 sec.,
Settings range
0 - 24
0 - 60
Monday to Sunday
01: Room and floor temp.
02: Only floor temp.
03: Only room temp*
20-35° C
(only for 01 & 02 in P04)
0: Disable; 1: Enable;
0: Disable; 1: Enable;
5-9° C
0: Disable; 1: Enable;
18-29° C
0: Disable; 1: Enable;
Default
00:
:00
MON
2
33
1
1
5
0
23
0
21