Moving
When all accessible surfaces from one position
have been scraped clean, the equipment is
moved to the next scaffold post or wall section.
To move the equipment:
(1) Lock the arm for transport
(2) Twist the locking handle
(3) Flip the safety clip, detach the arm and lift it
from the vertical stand
(4) Free the positioning lock from the stand and
move to the next stand.
- Fasten the arm to the vertical stand and flip
over the safety clip, twist the locking handle,
free up and move the transporation bracket.
When mounting on a facade using a facade
mount, the same steps apply; however,
the facade mount is removed from the wall
and is moved while attached to the scaffold
mount and tube.
Always allow the heater to
cool before moving it.
Caution!
Never use the device with the heating surface
directed downward.
Powerful re-radiated heat from below causes
the device quickly to become overheated and
its components damaged.
Overheating protection
Each side of the device has, independently of the other side, its own
overheating protection. If the overheating protection is triggered,
the current is cut off and the indicator lamp on each power switch turns off.
Set the power switch to the OFF position and allow the device
to cool completely.
Then reset the overheating protection by pressing the button located
below the power cord.
Turn the device back on according the instructions for connection / heating.
1
3
ENG 9
Facade mount
4
2
Reset-button for
anti-overheat function
4
Need help?
Do you have a question about the SH IR System Professional T and is the answer not in the manual?