Setting Of Numeric Parameter (Numeric Param.); Configuration Of Numeric Parameters - Canon Super G3 FAX Board-AS Service Manual

Table of Contents

Advertisement

Setting of Numeric Parameter (NUMERIC Param.)

Configuration of Numeric Parameters

No.
002
RTN transmission condition (1)
003
RTN transmission condition (2)
004
RTN transmission condition (3)
005
NCC pause time (before ID code)
006
NCC pause time (after ID code)
007
Prepose time at the time of making a call
009
Comparing the number of digits between the sender's telephone number
and the receiver's telephone number
010
Line connection identification time
011
T.30 T1 timer (for reception)
013
T.30 EOL timer
015
Hooking detection time
016
Time until a temporary response is obtained when switching FAX/TEL
017
Pseudo RBT signal pattern ON time
018
Pseudo RBT signal pattern OFF time (short)
019
Pseudo RBT signal pattern OFF time (long)
020
Pseudo CI signal pattern ON time
021
Pseudo CI signal pattern OFF time (short)
022
Pseudo CI signal pattern OFF time (long)
023
CNG detection level when switching FAX/TEL
024
Pseudo RBT transmission level when switching FAX/TEL
025
CNG monitoring time when the answering phone connection function is
set
026
Silent detection level when the answering phone connection function is
set
027
V.21 low-speed flag preamble detection time
028
Off-hook PCB duty settings
080
Transmission number restriction: Outside line transmission number *1
*1 : Supported on the platform version 307 or later
002: RTN transmission condition (1)/003: RTN transmission condition (2)/004: RTN transmission
condition (3)
Set the RTN signal transmission condition.
Sssw Menu
Num
Ncu Type IPFAX Print Clear Test
<1/10>
← yyyyy {aaaaa bbbbb}
001
xxxxx
xxxxx
← yyyyy {aaaaa bbbbb}
002
xxxxx
← yyyyy {aaaaa bbbbb}
003
← yyyyy {aaaaa bbbbb}
004
xxxxx
xxxxx
← yyyyy {aaaaa bbbbb}
005
006
xxxxx
← yyyyy {aaaaa bbbbb}
007
xxxxx
← yyyyy {aaaaa bbbbb}
008
xxxxx
← yyyyy {aaaaa bbbbb}
Function
35
Report
<READY>
OK
Setting range
1 to 99%
2 to 99 times
1 to 99 lines
1 to 60 sec
1 to 60 sec
0 to 9999 (x 10 ms)
0 to 20 digits
0 to 9999 (x 10 ms)
0 to 9999 (x 10 ms)
500 to 3000 (x 10 ms)
0 to 999
0 to 9
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 7
10 to 20 (TYPE =
STANDARD)
20 (-10 ms)
1 to 99%
0 to 9999
5. Service Mode
Default value
10
15
12
4
4
0
0
5500
3500
1300
120
4
100
0
200
100
0
200
4
20
0
0 (50%)
0

Advertisement