Service Error Code - Canon Super G3 FAX Board-AS Service Manual

Table of Contents

Advertisement

Service Error Code

Code
##3016
[T/R] An instruction of disconnec-
tion (BYE) was received from the
network at an unexpected time.
*1: G3FAX
*2: IPFAX
No.*1
No.*2
##100
##3100
##101
##3101
##102
##3102
##103
##3103
##104
##3104
##106
##3106
##107
##3107
##109
##3109
##111
##3111
##114
##3114
##116
##3116
##200
##3200
##201
##3201
##204
##3204
##220
##3220
##223
##3223
##224
##3224
##226
##3226
##227
##3227
##229
##3229
##230
##3230
##231
##3231
##232
##3232
##237
##3237
##238
##3238
##261
##3261
##280
##3280
##281
##3281
##282
##3282
##283
##3283
##284
##3284
##285
##3285
##286
##3286
##287
##3287
##288
##3288
##289
##3289
Cause
Perform a communication again.
T/R
[T]
at time of transmission, the procedural signal has been transmitted more than speci-
fied.
[T/R]
the modem speed does not match that of the other party.
[T]
at time of transmission, fall-back cannot be used.
[R]
at time of reception, EOL cannot be detected for 5 sec (15 sec if CBT).
[T]
at time of transmission, RTN or PIN is received.
[R]
at time of reception, the procedural signal is received for 6 sec while in wait for the
signal.
[R]
at time of reception, the transmitting party cannot use fall-back.
[T]
at time of transmission, a signal other than DIS, DTC, FTT, CFR, or CRP is received,
and the procedural signal has been sent more than specified.
[T/R]
memory error has occurred.
[R]
at time of reception, RTN is transmitted.
[T/R]
Disconnection of loop current was detected during communication.
[R]
at time of reception, no image carrier is detected for 5 sec.
[T/R]
DCN is received outside the normal parity procedure.
[T]
DTC without transmission data is received.
[T/R]
system error (main program out of control) has occurred.
[T/R]
while a communication is under way, the line is cut.
[T/R]
in communication, an error has occurred in the procedural signal.
[T/R]
the stack printer has fallen outside the RAM area.
[R]
An attempt was made to record a file without image.
[R]
the recording unit has remained locked for 1 min.
[T/R]
A unit for controlling the display has malfunctioned.
[T/R]
A unit for controlling the Control Panel buttons has malfunctioned.
[T]
encoding error has occurred.
[R]
decoding error has occurred.
[R]
the print control unit is out of order.
[T/R]
system error has occurred.
[T]
at time of transmission, the procedural signal has been transmitted more than speci-
fied.
[T]
at time of transmission, the procedural signal has been transmitted more than speci-
fied.
[T]
at time of transmission, the procedural signal has been transmitted more than speci-
fied.
[T]
at time of transmission, the procedural signal has been transmitted more than speci-
fied.
[T]
at time of transmission, DCN is received after transmission of TCF.
[T]
at time of transmission, DCN is received after transmission of EOP.
[T]
at time of transmission, DCN is received after transmission of EOM.
[T]
at time of transmission DCN is received after transmission of MPS.
[T]
after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or RTN has been
received.
[T]
after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or RTN has been
received.
Remedy
Description
13
4. Error/Jam/Alarm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super g3 fax board-as2

Table of Contents