Advertisement

TSOL-MP3000/MP2250/MS3000
TSOL-MP3000
TSOL-MP2250
TSOL-MS3000
V1.0
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSOL-MP3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tsun TSOL-MP3000

  • Page 1 TSOL-MP3000/MP2250/MS3000 TSOL-MP3000 TSOL-MP2250 TSOL-MS3000 V1.0 - 1 -...
  • Page 2: Trademarks And Permissions

    To ensure optimal reliability and meet warranty requirements, the TSUN Micro inverter must be installed according to the instructions in this manual. For warranty text refer to www.tsun-ess.com. © 2022 TSUNESS Co., Ltd All rights reserved.
  • Page 3: Table Of Contents

    Microinverter Installation ..............................- 9 - Pre-installation Check ....................................- 9 - Installation Steps ......................................- 10 - TSUN Monitoring System .............................. - 16 - Installer ........................................- 16 - End User ........................................- 17 - Remote Active Power Control ............................- 18 - Self-Test Function for Italy .............................
  • Page 4: Read This First

    TSOL-MP3000/MP2250/MS3000 Read This First Dear customer, thank you for choosing the TITAN series micro inverter from TSUN. We hope you will find our products meet your needs for renewable energy. Meantime, we appreciate your feedback regarding our products. A solar micro inverter, or simply micro inverter, is a plug-and-play device used in photovoltaics, that converts direct current (DC) generated by a single solar module to alternating current (AC).
  • Page 5 TSOL-MP3000/MP2250/MS3000 · CAUTION indicates that the described operation must not be carried out. The reader should stop using and fully understand the operations explained before proceeding. The symbols on the micro inverter are listed below and illustrated in detail. Symbol...
  • Page 6: System Introduction

    The micro inverter is integrated with the Wi-Fi module and connects to the home Wi-Fi router directly. Users can monitor the power generation of the system by TSUN monitoring App. V1.0 - 6 -...
  • Page 7: Product Description

    TSOL-MP3000/MP2250/MS3000 Product Description Mounting Hole Antenna Grounding Hole Status Light DC Cables Vent Valve AC Cable Datasheet Model MP2250 MP3000 MS3000 Input Data (DC) 4 Connectors 6 Connectors 4 Connectors Quantity of Input 4 Panels 5 - 6 Panels 7 - 8 Panels...
  • Page 8 Integrated Over-heat protection Integrated Mechanical Data Dimensions (W×H×D mm) 355 * 342 * 58 Weight [kg] General Data Display LED indicators; TSUN APP+WEB Communication built-in WiFi module Type of Isolation Transformerless Type of Enclosure IP67 Cooling Natural convection Operating Ambient Temperature -25 ~ +65 (derating of over 50°C Ambient Temperature)
  • Page 9: Microinverter Installation

    Pre-installation Check Check the Package Although TSUN’s micro inverters have surpassed stringent testing and are checked before they leave the factory, it is uncertain that the micro inverters may suffer damage during transportation. Please check the package for any obvious signs of damage, and if such evidence is present, do not open the package and contact your dealer as soon as possible.
  • Page 10: Installation Steps

    TSOL-MP3000/MP2250/MS3000 equipment.  It’s recommended to install micro inverter on structures underneath the photovoltaic modules so that they work in the shade without touching the rooftop. Installation Steps DANGER ·Only qualified personnel should install, troubleshoot, or replace TITAN micro inverters or the cable and accessories.
  • Page 11 TSOL-MP3000/MP2250/MS3000 The micro inverter can also be mounted on the wall (vertically) using the optional support. In this case, first, fix the bracket to the wall with a pair of screws, and then fix the micro inverter to the bracket with one pair of nut screws.
  • Page 12 TSOL-MP3000/MP2250/MS3000 WARNING ·Ensure that all AC cables are correctly wired and that none of the wires are pinched or damaged. ·Use AWG 12 ( 4 mm²) cable for AC end cable. CAUTION ·The installation technician is responsible for selecting a kind of AC cable and connecting the micro-inverter system to the home distribution network correctly.
  • Page 13 ·Use MC4 compatible DC connectors in the inverter side of the DC extension cable, or get the DC connectors from TSUN. ·Contact PV module manufacturers for the requirements of the DC connectors in the module side of the DC extension cable.
  • Page 14 TSOL-MP3000/MP2250/MS3000 modules in series. Step 5. Make an installation map CAUTION ·If there is more than one installation site, please make the installation map separately and give a clear description of the installation site. ·The row of the table corresponds to the shorter side of the PV module and the column of the table corresponds to the longer side of the PV module.
  • Page 15 TSOL-MP3000/MP2250/MS3000 ·Only qualified personnel should connect this system to the utility grid. CAUTION ·Do not connect the micro inverter(s) to the grid, nor energize the AC circuit(s) until you have completed all installation procedures and have received prior approval from the electricity utility company.
  • Page 16: Tsun Monitoring System

    TSUN Monitoring System TITAN series micro inverter has an integrated monitoring module inside. The micro inverter will directly connect to the router (Wi-Fi Version). Users can use the TSUN Smart APP or enter the TSUN website to monitor the micro inverter.
  • Page 17: End User

    TSOL-MP3000/MP2250/MS3000 User Guidance of TSUN Monitoring System End User Visit “Google Play” or “Apple Store” and “TSUN SMART”. Download and install it in the mobile phone. TSUN Smart Register a new account in TSUN SMART. Visit https://www.tsun-ess.com/File/$random-2023-09-16-090024-_912he0N or Scan the QR code below to find the latest User Guidance of TSUN SMART.
  • Page 18: Remote Active Power Control

    (input port) to cease the output of active power or limit active power to a regulated level. This logic input can be the RS485 port, Ethernet port, and so on. TSUN micro inverter provides an extra power control device that contains an RS485 port for this remote active power control. For more information, refer to the “User Manual of TSUN power control device”.
  • Page 19: Fault Code And Troubleshooting

    200KΩ. IsoFault Make sure the grounding connection of the inverter is reliable. If this fault appears continuously, please contact the TSUN service. PV1VoltOver_Fault PV2VoltOver_Fault Check the voltage of the PV module and make sure that the...
  • Page 20: Maintenance Guide

    This is an internal fault. Disconnect the AC power to restart the micro inverter. 24-25 Fault24 - 25 If this fault appears continuously, please contact the TSUN service. Check the open-circuit voltages of the module and make sure it is below the maximum DC input voltage of the...
  • Page 21: Storage And Dismantling

    TSOL-MP3000/MP2250/MS3000 Storage and Dismantling  If the equipment is not used immediately or is stored for long periods, check whether it is correctly packed. The equipment must be stored in well-ventilated indoor areas that do not have characteristics that might damage the components of the equipment.
  • Page 22: Recycling And Disposal

    TSOL-MP3000/MP2250/MS3000 Recycling and Disposal This device should not be disposed of as residential waste. A Micro inverter that has reached the end of its life is not required to be returned to the dealer. Users must find an approved collection and recycling facility in the area.
  • Page 23: Distributor Responsibility

    Within the warranty period of the micro inverter, the invoice and date of purchase are required for the service. Besides, the trademark on the product should be visible, otherwise, a warranty is not available. More information can be found in TSUN Warranty Policy. V1.0 - 23 -...
  • Page 24 TSOL-MP3000/MP2250/MS3000 V1.0 - 24 -...

This manual is also suitable for:

Tsol-mp2250Tsol-ms3000Titan series

Table of Contents

Save PDF