Phono; Auto Stby (Auto Standby); Att Level (Attenuation Level) - Marantz PM-12 SE Owner's Manual

Integrated amplifier
Hide thumbs Also See for PM-12 SE:
Table of Contents

Advertisement

PHONO

Sets the phono equalizer of this unit according to the type of
the turntable cartridge to be connected.
MM
Set this for an MM cartridge.
(Default):
MC:
Set this for an MC cartridge.
NOTE
The audio is muted for around 4 seconds when this setting
0
is changed.

AUTO STBY (Auto Standby)

Sets whether to automatically switch the unit to the standby
mode when there is no input signal and operation for 30
minutes.
ON
Enable Auto Standby mode.
(Default):
OFF:
Disable Auto Standby mode.
The display will show the remaining time for three minutes
0
before the units enters standby mode.
In F.C.B.S. connection, only the ID 1 master unit activates
0
Auto Standby mode. If the ID 1 master unit is operated with
no audio input, set the Auto Standby mode to off.
ATT LEVEL (Attenuation
Level)
Sets how far the volume is decreased when the MUTE button
is pressed.
-20 dB / -40 dB / -∞(Default: -∞)
"ATT" appears on the display if the MUTE button is
0
pressed when -20 dB or -40 dB is set.
"MUTE" appears on the display if the MUTE button is
0
pressed when -∞ is set.
Press the MUTE button again to cancel the setting and
0
return to the original volume.
ENGLISH
20

Advertisement

Table of Contents
loading

Table of Contents