Installation alternatives

The drive must be installed on the wall or an enclosure. There are three alternative
ways to install it:
Vertical
Note: Do not install the drive upside down.
c
Frame
size
Above (a) 1)
mm
in
R1
65
2.56
R2
65
2.56
R3
65
2.56
R4
53
2.09
R5
75
2.95
R6
155
6.10
R7
155
6.10
R8
155
6.10
R9
200
7.87
1)
Free space above is measured from the frame, not from the hood used in
UL Type 12 frames.
a
b
Vertical installation - Free space
IP21 (UL Type 1)
Below (b) 2)
Beside (c) 3)
mm
in
mm
86
3.39
150
86
3.39
150
53
2.09
150
200
7.87
150
200
7.87
150
300
11.81
150
300
11.81
150
300
11.81
150
300
11.81
150
Mechanical installation 61
b
IP55 (UL Type 12)
Above (a) 1)
Below (b) 2)
in
mm
in
mm
5.91
137
5.39
116
5.91
137
5.39
116
5.91
200
7.87
53
5.91
53
2.09
200
5.91
100
3.94
200
5.91
155
6.10
300
5.91
155
6.10
300
5.91
155
6.10
300
5.91
200
7.87
300
b
Beside (c) 3)
in
mm
in
4.57
150
5.91
4.57
150
5.91
2.09
150
5.91
7.87
150
5.91
7.87
150
5.91
11.81
150
5.91
11.81
150
5.91
11.81
150
5.91
11.81
150
5.91